Measures of body composition via Dual-energy X-ray absorptiometry, ultrasound and skinfolds are not impacted by the menstrual cycle in active eumenorrheic females

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
6
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
6
1

Relationship

1
6

Authors

Journals

citations
Cited by 11 publications
(6 citation statements)
references
References 33 publications
0
6
0
Order By: Relevance
“…Furthermore, activity monitors should be integrated into future studies so as to better confirm the impact of physical activity guidance on both incidental and structured physical activity, in place of the subjective nature of a training diary. Given assessments were undertaken across ~48 hour period, consideration was not given to phase of menstrual cycle amongst women volunteers, given this does not influence DXA estimates of body composition (Ong et al, 2022), or any effect is trivial (Thompson et al, 2021).…”
Section: Discussionmentioning
confidence: 99%
“…Furthermore, activity monitors should be integrated into future studies so as to better confirm the impact of physical activity guidance on both incidental and structured physical activity, in place of the subjective nature of a training diary. Given assessments were undertaken across ~48 hour period, consideration was not given to phase of menstrual cycle amongst women volunteers, given this does not influence DXA estimates of body composition (Ong et al, 2022), or any effect is trivial (Thompson et al, 2021).…”
Section: Discussionmentioning
confidence: 99%
“…A hospital-grade digital ear thermometer (Braun Thermoscan 7 IRT6520 Thermometer) and digital axilla thermometer (Surgipack Digital Thermometer 6344, Vega Technologies, China) was used to validate the temperature readings from the wearable sensors. These devices are commercially available for hospital use, and they are regarded as a benchmark for temperature monitoring accuracy [ 43 , 45 ]. To receive the most accurate reference temperature readings from this device, all the measurements were conducted by an experienced registered nurse.…”
Section: Methodsmentioning
confidence: 99%
“…Our group has also previously demonstrated this method to reliably measure SAT thickness across the menstrual cycle in active eumenorrheic females (Ong et al, 2022b), as well as being robust against changes in hydration status or acute food or fluid intake (Ong et al, 2022a). This finding holds significance for standardised B‐mode US as a physique assessment method.…”
Section: Introductionmentioning