2020
DOI: 10.1016/j.sna.2020.112159
|View full text |Cite
|
Sign up to set email alerts
|

Measuring and calibrating of the parasitic mismatch in MEMS accelerometer based on harmonic distortion self-test

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
5

Citation Types

0
10
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 17 publications
(10 citation statements)
references
References 19 publications
0
10
0
Order By: Relevance
“…However, they ignored the parasitic capacitance between the electrodes in the readout circuit. Chen D. et al proposed a method to identify and calibrate parasitic mismatches based on a digital, closed-loop EM-Δ (electromechanical sigma delta) accelerometer system [ 17 ]. Consequently, their method is only applicable to closed-loop configurations.…”
Section: Introductionmentioning
confidence: 99%
“…However, they ignored the parasitic capacitance between the electrodes in the readout circuit. Chen D. et al proposed a method to identify and calibrate parasitic mismatches based on a digital, closed-loop EM-Δ (electromechanical sigma delta) accelerometer system [ 17 ]. Consequently, their method is only applicable to closed-loop configurations.…”
Section: Introductionmentioning
confidence: 99%
“…According to the detection principle, micro-accelerometers can be divided into piezoresistive [ 22 ], piezoelectric [ 23 ], resonant [ 24 ], capacitive [ 25 ], and other forms. Among them, capacitive accelerometers have the advantages of high accuracy [ 26 ], low-noise [ 27 ], low temperature sensitivity [ 28 ], low power consumption [ 29 ], and a simple structure [ 30 ].…”
Section: Introductionmentioning
confidence: 99%
“…It's well known that, there is an increasing demand for improving the accuracy of the calibration system (Chen et al, 2020a(Chen et al, , 2020bSoriano et al, 2020). The use of the appropriate calibration algorithm has been proved to be effective for improving the calibration accuracy.…”
Section: Introductionmentioning
confidence: 99%
“…Xue et al (2020) show that the combined PSO-sequential quadratic programming algorithm could reach the highest accuracy for the parameter calibration of the storm water management model and could obtain the most optimal parameter. The genetic algorithm (GA)-deep neural network non-linear regression prediction model has been proposed to achieve a robot's high-precision positioning performance under any external payload (Chen et al, 2020a(Chen et al, , 2020b. Feng et al (2020aFeng et al ( , 2020b proposed a novel optimisation framework of grid search moving window-linear predictive coding-GA for near-infrared (NIR) calibration, and experiments have shown that this algorithm provides an effective method for improving the performance of the NIR calibration models.…”
Section: Introductionmentioning
confidence: 99%