Measuring fluid flow and heat output in seafloor hydrothermal environments

Abstract: We review techniques for measuring fluid flow and advective heat output from seafloor hydrothermal systems and describe new anemometer and turbine flowmeter devices we have designed, built, calibrated, and tested. These devices allow measuring fluid velocity at high‐ and low‐temperature focused and diffuse discharge sites at oceanic spreading centers. The devices perform at ocean floor depths and black smoker temperatures and can be used to measure flow rates ranging over 2 orders of magnitude. Flow velocity i… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

3
18
0
1

Year Published

2016
2016
2023
2023

Publication Types

Select...
5
2

Relationship

1
6

Authors

Journals

citations
Cited by 27 publications
(22 citation statements)
references
References 91 publications
3
18
0
1
Order By: Relevance
“…Averaging all along axis, temperature measurements ( Figure 2) in the 1900-2100 m depth range gives an average temperature anomaly of 0.0438C, similar to previous measurements [e.g., Baker and Massoth, 1987;Thomson et al, 1992;Kellogg and McDuff, 2010]. Based on published data, black smoker vent fluid temperatures at Endeavour are between 300 and 3808C [Butterfield et al, 1994;Seyfried et al, 2003;Bao et al, 2008;Lin et al, 2016;Germanovich et al, 2015]. A single vent in the Main Endeavour field has been monitored through the ONC cabled observatory and has maintained a temperature of 333 6 28C (1r) over a 6 year interval (September 2010 to July 2016; data at http://dmas.uvic.ca/DataSearch) consistent with the published vent fluid temperatures.…”
Section: Oceanographic Datasupporting
confidence: 82%
“…Averaging all along axis, temperature measurements ( Figure 2) in the 1900-2100 m depth range gives an average temperature anomaly of 0.0438C, similar to previous measurements [e.g., Baker and Massoth, 1987;Thomson et al, 1992;Kellogg and McDuff, 2010]. Based on published data, black smoker vent fluid temperatures at Endeavour are between 300 and 3808C [Butterfield et al, 1994;Seyfried et al, 2003;Bao et al, 2008;Lin et al, 2016;Germanovich et al, 2015]. A single vent in the Main Endeavour field has been monitored through the ONC cabled observatory and has maintained a temperature of 333 6 28C (1r) over a 6 year interval (September 2010 to July 2016; data at http://dmas.uvic.ca/DataSearch) consistent with the published vent fluid temperatures.…”
Section: Oceanographic Datasupporting
confidence: 82%
“…Note that the velocity perturbation at the seafloor ( z=0) is of particular interest since it can be measured by seafloor instruments such as a direct flow meter (e.g., Germanovich et al, ) or camera systems that use image analysis methods (e.g., Crone et al, ; Mittelstaedt et al, ). It is expressed as: u1|0,t=k1lπμD1 |a1b1pTeiωt . …”
Section: A Model For Tidal Modulation Of Hydrothermal Systems With Dementioning
confidence: 99%
“…The heat output obtained from equation (7) is much less than observed at high-temperature hydrothermal systems at mid-ocean ridges, which is typically~100 MW [e.g., Lowell et al, 2013]. The predicted estimates Geophysical Research Letters 10.1002/2016GL072326 of mass flow and heat output at LCHF could be tested by direct measurement using flow meters and temperature probes deployed from a human-occupied vehicle or remotely operated vehicle or other devices [e.g., Germanovich et al, 2015].…”
Section: Resultsmentioning
confidence: 99%