2020
DOI: 10.1016/j.jeurceramsoc.2020.01.061
|View full text |Cite
|
Sign up to set email alerts
|

Mechanical testing of hydroxyapatite filaments for tissue scaffolds preparation by fused deposition of ceramics

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
17
0
1

Year Published

2021
2021
2023
2023

Publication Types

Select...
5
2

Relationship

0
7

Authors

Journals

citations
Cited by 25 publications
(18 citation statements)
references
References 21 publications
0
17
0
1
Order By: Relevance
“…Foi observado que o ácido esteárico foi fundamental para o processamento, pois além de permitir e remoção do veículo orgânico (debinding). Finalmente, a etapa de sinterização sempre pode ser otimizada de acordo com sua composição química, presença de veículos orgânicos, temperatura utilizada e tempo de permanência, viabilizando um processo de obtenção de peças cada vez mais eficiente, com propriedades adequadas para cada aplicação [44].…”
Section: Resultsunclassified
“…Foi observado que o ácido esteárico foi fundamental para o processamento, pois além de permitir e remoção do veículo orgânico (debinding). Finalmente, a etapa de sinterização sempre pode ser otimizada de acordo com sua composição química, presença de veículos orgânicos, temperatura utilizada e tempo de permanência, viabilizando um processo de obtenção de peças cada vez mais eficiente, com propriedades adequadas para cada aplicação [44].…”
Section: Resultsunclassified
“…[184] Another important variable in buckling phenomena is the slenderness ratio, which, for a given filament diameter, is defined by the unsupported length of the sample, that is, by the distance of the sample grips in compression tests. [184] In this regard, Janek et al [188] recently compared the compressive behavior of several filaments as measured under varying test conditions. It was demonstrated that, regardless of the composition of the filament (including two different polyvinyl alcohol (PVA) filaments loaded with 50 wt% of hydroxyapatite and a commercial PLA filament loaded with about 27 wt% of gypsum), the compressive strength drastically decreased when the nominal distance of the sample grips was increased from 16 to 36 mm and then up to 76 mm.…”
Section: From the Feeding Mechanism To The Liquefier Entrancementioning
confidence: 99%
“…With the filament diameter being constant, the increasing gripping distance resulted in a longer unsupported length and, ultimately, in a higher slenderness ratio, which induced a stronger tendency to Euler buckling. [ 188 ]…”
Section: Feeding and Flowing Through The Hot‐endmentioning
confidence: 99%
See 1 more Smart Citation
“…FDM requires materials that can be processed into polymer filaments with a high enough viscosity to build and a low enough viscosity to extrude . FDM also has an indirect printing method for ceramics, namely, fused deposition of ceramics (FDC) . Indirect printing increases the types of materials that can be used for SLA/DLP/FDM to a certain extent, but the current applications in dental implants are still relatively limited and need to be supported by more clinical experiments.…”
Section: Am Technologiesmentioning