2021
DOI: 10.3390/jcm10173853
|View full text |Cite
|
Sign up to set email alerts
|

Mechanical Thrombectomy in Acute Terminal Internal Carotid Artery Occlusions Using a Large Manually Expandable Stentretriever (Tiger XL Device): Multicenter Initial Experience

Abstract: Background: The recently introduced Tigertriever XL Device for treatment of cerebral vessel occlusions combines manual adjustability and maximum length in one device. In this study, we report our initial experience with the Tigertriever XL in terminal ICA occlusions. Methods: Retrospective multicenter analysis of acute terminal ICA occlusions treated by mechanical thrombectomy using the Tigertriever XL Device. Results: 23 patients were treated using the Tigetriever XL due to an acute occlusion of the terminal … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2

Citation Types

0
18
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
7

Relationship

1
6

Authors

Journals

citations
Cited by 10 publications
(18 citation statements)
references
References 25 publications
0
18
0
Order By: Relevance
“…Recently, a large manually expandable stent retriever achieved 34.8% (8 of 23) of FPE in ICA terminus occlusion with successful recanalization in 95.7% (22 of 23) and mRS 0 to 2 in 26.1% (6 of 23) of patients. 25 FPE, as a modifiable factor, warrants further improvements to achieve better clinical outcomes in thrombectomy for ICA terminus occlusions.…”
Section: Discussionmentioning
confidence: 99%
See 2 more Smart Citations
“…Recently, a large manually expandable stent retriever achieved 34.8% (8 of 23) of FPE in ICA terminus occlusion with successful recanalization in 95.7% (22 of 23) and mRS 0 to 2 in 26.1% (6 of 23) of patients. 25 FPE, as a modifiable factor, warrants further improvements to achieve better clinical outcomes in thrombectomy for ICA terminus occlusions.…”
Section: Discussionmentioning
confidence: 99%
“…Collateral flow can modify endovascular treatment efficacy by facilitating thrombus retrieval and lowering the number of device passes. 22 In addition, under different collateral flows, even the association between the clot burden score and functional outcome (17,25) for patients with 90-day mRS = 6 vs 18 (14,22) for patients with 90-day mRS < 6.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…Tigertriver XL is the newest and the largest device in the portfolio. It is designed to remove clots from arteries up to 9 mm in diameter (mostly from an internal carotid artery) (9). Tigertriever has had a CE mark since 2016 and has shown promising results regarding its efficiency and safety, mostly in singlecenter studies (7,10).…”
Section: Introductionmentioning
confidence: 99%
“…Tigertriver XL is the newest and the largest device in the portfolio. It is designed to remove clots from arteries up to 9 mm in diameter (mostly from an internal carotid artery) ( 9 ).…”
Section: Introductionmentioning
confidence: 99%