2019
DOI: 10.1016/j.jvir.2018.08.005
|View full text |Cite
|
Sign up to set email alerts
|

Mechanical Thrombectomy Using the Solitaire AB Device for Acute Embolic Mesenteric Ischemia

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

1
9
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
7
1

Relationship

2
6

Authors

Journals

citations
Cited by 12 publications
(10 citation statements)
references
References 19 publications
1
9
0
Order By: Relevance
“…Clot retrieval is performed by the deployment of Solitaire AB directly into an occluded artery with a diameter of 5.3 ± 0.6 mm, in order to improve the thrombectomy efficacy and reduce the risk of further distal embolization, additional thromboaspiration using a 6-F guiding catheter is combined in this study. This coupled technique appears to have the functions including both stent deployment, which enables immediate flow restoration, and an aspiration device, 11 which allows definitive clot removal from an occluded artery.…”
Section: Discussionmentioning
confidence: 99%
See 2 more Smart Citations
“…Clot retrieval is performed by the deployment of Solitaire AB directly into an occluded artery with a diameter of 5.3 ± 0.6 mm, in order to improve the thrombectomy efficacy and reduce the risk of further distal embolization, additional thromboaspiration using a 6-F guiding catheter is combined in this study. This coupled technique appears to have the functions including both stent deployment, which enables immediate flow restoration, and an aspiration device, 11 which allows definitive clot removal from an occluded artery.…”
Section: Discussionmentioning
confidence: 99%
“…The Solitaire AB device (Medtronic, Minneapolis, Minnesota, USA) is a self-expanding stent that can facilitate clot retrieval. 11 Mechanical thrombectomy using Solitaire AB device has been proven to be an important adjunctive reperfusion therapy for acute ischemic stroke (AIS) 12 and acute mesenteric ischemia (AMI). 11 Yet, the reports in the setting of ALI remain limited.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…The Solitaire AB is a laser-cut, selfexpanding, and fully recapture able, split-design nitinol device which has been routinely used in mechanical thrombectomy for acute cerebral infarction. In addition to craniocerebral blood vessels, Solitaire AB stent has also been used to retrieve superior mesenteric artery embolism [10]. Studies have shown that for acute ischemic stroke, the vascular recanalization rate and prognosis of stent thrombectomy are signi cantly better than those of non-stent PMT in all PMT procedures [11].…”
Section: Discussionmentioning
confidence: 99%
“…8 Advantages specific to the Trevo XP include circumferential large cells, a soft tapered flexible distal tip for improved distal placement, full length radiopacity, and hydrophilic coating. 16 Drawbacks for using these SRs include small caliber size as well as device use comfort level for practitioners who do not often use this device. In patients with tortuous vessels, extensive calcified atherosclerosis, or long segment occlusion, EVT may not be feasible.…”
Section: Sr History Technique and Designmentioning
confidence: 99%