2016
DOI: 10.15199/48.2016.11.15
|View full text |Cite
|
Sign up to set email alerts
|

Mechanisms of electric arc detection based on current waveform spectrum and incremental decomposition analysis

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
5
0

Year Published

2021
2021
2023
2023

Publication Types

Select...
2

Relationship

1
1

Authors

Journals

citations
Cited by 2 publications
(5 citation statements)
references
References 13 publications
0
5
0
Order By: Relevance
“…In the formulas, 𝑁 𝐷𝑐𝑜𝑛𝑣 is the amount of calculation in the depth separable convolution process; 𝑃 𝐷𝑐𝑜𝑛𝑣 is the parameter quantity in the process of depth separable convolution; the ratio of the amount of calculation, the number of parameters in the depth separable convolution and the standard convolution can be obtained by Formulas (10) and (11). Figure 5a describes the deep convolution process, which is grouped according to the channel of the input feature map.…”
Section: Depth Separable Convolutionmentioning
confidence: 99%
See 1 more Smart Citation
“…In the formulas, 𝑁 𝐷𝑐𝑜𝑛𝑣 is the amount of calculation in the depth separable convolution process; 𝑃 𝐷𝑐𝑜𝑛𝑣 is the parameter quantity in the process of depth separable convolution; the ratio of the amount of calculation, the number of parameters in the depth separable convolution and the standard convolution can be obtained by Formulas (10) and (11). Figure 5a describes the deep convolution process, which is grouped according to the channel of the input feature map.…”
Section: Depth Separable Convolutionmentioning
confidence: 99%
“…Especially with the increasing proportion of non-linear loads in lowvoltage distribution systems [9], the normal current under certain operating conditions is likely to be very close to the time domain and frequency domain of the fault arc, which easily makes the arc detection wrong and missed. Michal et al [10,11] proposed an algorithm for the incremental decomposition of a signal over time, which is about seven times faster than the FFT and cheaper to implement than FFT in arc fault detection equipment.…”
Section: Introductionmentioning
confidence: 99%
“…The key to detecting an arc efficiently is to define the following parameters of FFT: The sampling frequency, length, and shape of the measuring window. Moreover, on the basis of the FFT results, it is crucial to select the bandwidth, as the area within the arc introduces the most harmonics in reference to the background noise present there all the time [66], and this also applies to AC arc detection devices [69].…”
Section: Spectrum Analysis In Electric Arc Detectionmentioning
confidence: 99%
“…In this study, measurements were acquired from the oscilloscope, not directly from an analog-to-digital converter, so additional signal pre-processing had to be conducted compared with [66]. All samples had to be divided by the value of the least significant bit of the oscilloscope's ADC, which was 0.12 mV.…”
Section: Proposed Algorithm Of Incremental Decomposition Of the Signa...mentioning
confidence: 99%
See 1 more Smart Citation