Mechanisms of Pelvic Floor Trauma During Vaginal Delivery

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
14
0
2

Year Published

2021
2021
2023
2023

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 8 publications
(16 citation statements)
references
References 25 publications
0
14
0
2
Order By: Relevance
“…From the 101 records included, 23 PFM dynamometers from 15 research groups were identified. PFM dynamometers were grouped into two categories: clinical PFM dynamometers ( n = 20, from 12 research groups), 7–26 meant for research settings, and personal PFM dynamometers ( n = 3, from three groups), which were commercially available and intended for patient use 27–29 …”
Section: Resultsmentioning
confidence: 99%
See 2 more Smart Citations
“…From the 101 records included, 23 PFM dynamometers from 15 research groups were identified. PFM dynamometers were grouped into two categories: clinical PFM dynamometers ( n = 20, from 12 research groups), 7–26 meant for research settings, and personal PFM dynamometers ( n = 3, from three groups), which were commercially available and intended for patient use 27–29 …”
Section: Resultsmentioning
confidence: 99%
“…Dynamometers were made of a wide range of materials. Specifically, nine dynamometers were made of aluminum, 7,8,16,19–21,23–25 one was made of plastic externally and steel internally, 17 two were made of stainless‐steel, 9,18 one was made of metal, 26 three out of plastic, 13–15 two out of polylactic acid, 11,12 one was made of acrylonitrile butadiene styrene and polycarbonate 10 and one was of unknown material (not reported) 22 . Of interest, the material used for the research PFM dynamometers appears to have shifted over time from aluminum and stainless‐steel to 3D‐printed plastic (polylactic acid, acrylonitrile butadiene styrene, and polycarbonate), which allows for more possibilities in device design.…”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…Other factors can be obesity, episiotomy, and weight of the baby, smoking, and diabetes [10] . Vaginal delivery may commence damage to the urinary continence mechanism either by direct injury to the muscles of pelvic floor or by damaging their motor innervations during a surgical procedure or by combination of both [11] . Behavioral techniques and lifestyle changes work well for certain types of stress urinary incontinence [12] .…”
Section: Introductionmentioning
confidence: 99%
“…According to the investigation [19], it can be found that delivery causes great damage to the maternals' PFM. The biomechanical analysis of the delivery process is helpful to study the mechanism of PFM injury.…”
Section: Introductionmentioning
confidence: 99%