Introduction
Varus collapse followed by osteosynthesis for distal femoral fractures with conventional implants has been well documented but is seldom mentioned in fractures managed with locking plates. The purpose of this study was to assess the incidence of varus collapse after treating complex supra-intercondylar fractures of the distal femur (AO type C3) using a Single Plate (SP) or Double Plate (DP) fixation technique.
Materials and methods
We retrospectively reviewed 357 patients with distal femoral fractures who were treated at our hospital between 2006 and 2017. After excluding cases of infection, malignancy, periprosthetic fracture, revision surgery, pediatric fracture, and extra-articular fracture, 54 patients were included in the study. All demographic data and radiological and clinical outcomes were reviewed and analyzed.
Results
There were 54 patients enrolled into this study with age from 15 to 85 years old (mean 41.6, SD = 19.9), and 32 of them were open fractures (59%). The patients were further divided into either an SP (n = 15) or a DP group (n = 39). Demographics, including age, sex, injury severity score, and open fracture type, were all compatible between the two groups. The overall nonunion rate was 25.9% (n = 14; 6 from the SP and 8 from the DP group; p = 0.175). The varus collapse rate was 9.3% (n = 5; 4 from the SP and 1 from the DP group (p = 0.018).
Conclusions
The varus collapse rate after osteosynthesis with a single lateral locking plate could be as high as 26.7% in AO type C3 fractures of the distal femur, which would be decreased to 2.6% by adding a medial buttress plate. Surgeons should consider DP fixation to avoid varus collapse in severely comminuted complete intra-articular fractures of the distal femur.