2000
DOI: 10.1002/(sici)1521-4109(20000301)12:4<262::aid-elan262>3.3.co;2-6
|View full text |Cite
|
Sign up to set email alerts
|

Mediated Oxidation and Determination of Gaseous Monomethyl Hydrazine in a Solid-State Voltammetric Cell Employing a Sol-Gel Electrolyte

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
7
0

Year Published

2001
2001
2013
2013

Publication Types

Select...
5

Relationship

1
4

Authors

Journals

citations
Cited by 5 publications
(7 citation statements)
references
References 0 publications
0
7
0
Order By: Relevance
“…Voltammetry was applied to measure gas-phase H 2 O 2 and hydrazine using mesoporous silica loaded with hygroscopic salts to control the amount of pore water and to pre-concentrate the analyte species, as mentioned above. 174,233 A rather unconventional gas-sensing method was introduced which employed measurement of the surface photo-voltage, a technique which is usually used in semiconductor physics for determination of mean free paths of minority charge carriers. By using mesoporous silica materials such as MCM-41 and SBA-16, NO and NO 2 gases were monitored in low concentrations at room temperature.…”
Section: Optical Gas Sensorsmentioning
confidence: 99%
“…Voltammetry was applied to measure gas-phase H 2 O 2 and hydrazine using mesoporous silica loaded with hygroscopic salts to control the amount of pore water and to pre-concentrate the analyte species, as mentioned above. 174,233 A rather unconventional gas-sensing method was introduced which employed measurement of the surface photo-voltage, a technique which is usually used in semiconductor physics for determination of mean free paths of minority charge carriers. By using mesoporous silica materials such as MCM-41 and SBA-16, NO and NO 2 gases were monitored in low concentrations at room temperature.…”
Section: Optical Gas Sensorsmentioning
confidence: 99%
“…An approach similar to that for the CO sensor was used for determination of hydrogen peroxide 356 and monomethyl hydrazine. 357 The hydrogen peroxide sensor used a basecatalysed sol-gel process (using TEOS) to cast the film over a three-electrode assembly. The working electrode was Pt.…”
Section: Application To Electrochemical Gas Sensorsmentioning
confidence: 99%
“…Advances in this ®eld were essentially reported by the Cox's group [125,138,205]. Unmodi®ed silica containing liquid microphases was used as a solid electrolyte for the amperometric sensing of gaseous carbon monoxide [125] and hydrogen peroxide [138].…”
Section: Gas Sensorsmentioning
confidence: 99%
“…Unlike the Na®on-based sensors, the xerogel ®lms provided an amperometric response that was independent of changes in humidity. When adding iron(II) or a mixed valenceruthenium oxide in the bulk of this solid electrolyte, mediated oxidation and determination of gaseous monomethyl hydrazine can be carried out by amperometry [205]. The sensor was also sensitive to other gases as sulfur and nitrogen oxides.…”
Section: Gas Sensorsmentioning
confidence: 99%