2012
DOI: 10.5495/wjcid.v2.i2.13
|View full text |Cite
|
Sign up to set email alerts
|

Medical errors, infection-control breaches and the use of adulterated and misbranded medical devices

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
3
0

Year Published

2013
2013
2015
2015

Publication Types

Select...
2

Relationship

0
2

Authors

Journals

citations
Cited by 2 publications
(3 citation statements)
references
References 22 publications
0
3
0
Order By: Relevance
“…This article's review of the medical literature presents a number of additional findings. First, it identified several reports that document outbreaks (and pseudo-outbreaks) of P. aeruginosa associated with a number of different types of reusable medical instruments, including bronchoscopes, gastrointestinal endoscopes and transrectal ultrasound-guided prostate biopsy equipment [9][10][11][12][13][14][15][16][17]. These instruments, however, unlike the arthroscopic shaver handpieces and inflow/outflow cannulae discussed by Tosh et al (2011), are damaged by heat, and for each of these reported outbreaks disease transmission was linked, not to ineffective steam sterilization, but to inadequate high-level disinfection or liquid chemical sterilization.…”
Section: Methodsmentioning
confidence: 99%
See 2 more Smart Citations
“…This article's review of the medical literature presents a number of additional findings. First, it identified several reports that document outbreaks (and pseudo-outbreaks) of P. aeruginosa associated with a number of different types of reusable medical instruments, including bronchoscopes, gastrointestinal endoscopes and transrectal ultrasound-guided prostate biopsy equipment [9][10][11][12][13][14][15][16][17]. These instruments, however, unlike the arthroscopic shaver handpieces and inflow/outflow cannulae discussed by Tosh et al (2011), are damaged by heat, and for each of these reported outbreaks disease transmission was linked, not to ineffective steam sterilization, but to inadequate high-level disinfection or liquid chemical sterilization.…”
Section: Methodsmentioning
confidence: 99%
“…These instruments, however, unlike the arthroscopic shaver handpieces and inflow/outflow cannulae discussed by Tosh et al (2011), are damaged by heat, and for each of these reported outbreaks disease transmission was linked, not to ineffective steam sterilization, but to inadequate high-level disinfection or liquid chemical sterilization. These latter two types of processes use a low-temperature liquid chemical disinfectant or sterilant to effect their outcome, and the cause of infection associated with either is often attributed to the terminal rinsing of heat-sensitive instruments with water that was contaminated with bacteria [10][11][12][13][14][15].…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation