2017
DOI: 10.3791/55298
|View full text |Cite
|
Sign up to set email alerts
|

Medical-grade Sterilizable Target for Fluid-immersed Fetoscope Optical Distortion Calibration

Abstract: We have developed a calibration target for use with fluid-immersed endoscopes within the context of the GIFT-Surg (Guided Instrumentation for Fetal Therapy and Surgery) project. One of the aims of this project is to engineer novel, real-time image processing methods for intra-operative use in the treatment of congenital birth defects, such as spina bifida and the twin-to-twin transfusion syndrome. The developed target allows for the sterility-preserving optical distortion calibration of endoscopes within a few… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
4
0

Year Published

2019
2019
2022
2022

Publication Types

Select...
3
1

Relationship

1
3

Authors

Journals

citations
Cited by 4 publications
(4 citation statements)
references
References 15 publications
0
4
0
Order By: Relevance
“…In addition, a relocalization module, multimapping, or dynamic method will help if tracking is lost due to rapid fetoscopic movements or fetal parts moving to the field of view. Finally, it was remarkable that most researchers did not take the fetoscopic camera's optical distortions into account, while approaches for fluid‐immersed fetoscopic camera calibration have been proposed 43,44 …”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…In addition, a relocalization module, multimapping, or dynamic method will help if tracking is lost due to rapid fetoscopic movements or fetal parts moving to the field of view. Finally, it was remarkable that most researchers did not take the fetoscopic camera's optical distortions into account, while approaches for fluid‐immersed fetoscopic camera calibration have been proposed 43,44 …”
Section: Discussionmentioning
confidence: 99%
“…Finally, it was remarkable that most researchers did not take the fetoscopic camera's optical distortions into account, while approaches for fluid-immersed fetoscopic camera calibration have been proposed. 43,44 Difficulties arise, however, when an attempt is made to implement the techniques in clinical practice. In addition, a lack of ground truth and big datasets may hinder the fast development of deep learning techniques.…”
Section: Reconstructionmentioning
confidence: 99%
“…We then followed the same procedure to calibrate the stereo-endoscope under water considering as such the adapted pinhole camera model (Nikitichev et al. 2017 ). We used the same set of underwater images to calibrate the orientation and distance of the flat refractive plane considering the flat refractive camera model (Agrawal et al.…”
Section: Methodsmentioning
confidence: 99%
“…We used a planar checkerboard and estimated both internal camera parameters and rigid pose between the cameras pair (Zhang 2000). We then followed the same procedure to calibrate the stereo-endoscope under water considering as such the adapted pinhole camera model (Nikitichev et al 2017). We Fig.…”
Section: Camera Pose Estimation Evaluationmentioning
confidence: 99%