Proceedings of 18th Annual International Conference of the IEEE Engineering in Medicine and Biology Society
DOI: 10.1109/iembs.1996.656927
|View full text |Cite
|
Sign up to set email alerts
|

Medical image-based design of an individualized surgical guide for pedicle screw insertion

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
10
0

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 14 publications
(10 citation statements)
references
References 3 publications
0
10
0
Order By: Relevance
“…The first report of RP-PSGs being used in orthopaedic surgery dates from 1997: a pedicle screw placement in the lumbar spine. 3 Since then, different authors presented cadaver and clinical studies for screws insertions in the thoracic, 51,53,57 cervical, 9,44,46,55,58,59 and lumbar spine. 3,10,11,38,56 Good screws insertion accuracy, shorter intervention time and cost savings are the main advantages reported by authors.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…The first report of RP-PSGs being used in orthopaedic surgery dates from 1997: a pedicle screw placement in the lumbar spine. 3 Since then, different authors presented cadaver and clinical studies for screws insertions in the thoracic, 51,53,57 cervical, 9,44,46,55,58,59 and lumbar spine. 3,10,11,38,56 Good screws insertion accuracy, shorter intervention time and cost savings are the main advantages reported by authors.…”
Section: Discussionmentioning
confidence: 99%
“…The use of RP processes to manufacture patient-specific surgical guides (RP-PSGs) specially designed for a specific patient can be traced back in 1997, when Van Brussel et al 3 reported the design, manufacture and use of the first individualised template for drilling trajectories when inserting pedicle screws into the vertebra of a human spine. In 1998, Radermacher et al 4 employed the stereolithography (SL) process to obtain the physical prototype of a PSG for pelvic osteotomies.…”
Section: Introductionmentioning
confidence: 99%
“…The same holds true for individual templates, which are designed to fit very well on the corresponding part of the skeleton so that the surgeon can accurately perform the planned action (e.g., sawing the top of the tibia). 17,22 Moreover, a new template has to be designed for every new application; the robot is general purpose and only the surgical plan entered into the workstation changes. On the other hand, robot systems using a mill can not only make bone cuts at the correct location but also improve the surface flatness; a flat surface is very important in operations like total knee replacement.…”
Section: Discussionmentioning
confidence: 99%
“…The first method concerns the part of the guide that interfaces with the bone surface. Van Brussel et al were the first to design patient‐specific spine surgical templates. These were later differentiated by Berry et al for cervical, thoracic, and lumbar levels.…”
Section: Introductionmentioning
confidence: 99%