2013
DOI: 10.1038/srep02796
|View full text |Cite
|
Sign up to set email alerts
|

Medium-term Outcomes of Cemented Prostheses and Cementless Modular Prostheses in Revision Total Hip Arthroplasty

Abstract: There is an increasing trend towards cementless modular femoral prostheses for revision hip replacement surgery, especially in patients with severe proximal femoral bone defects. However, for minor femoral bone defects, the benefit of cementless modular is not clear. We designed a retrospective cross-sectional study to compare outcomes of the two femoral implant designs. There were no significant differences in terms of visual analog pain scores, Harris hip scores, femoral bone restoration, stem subsidence, le… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
8
0

Year Published

2017
2017
2024
2024

Publication Types

Select...
6
2

Relationship

0
8

Authors

Journals

citations
Cited by 9 publications
(8 citation statements)
references
References 31 publications
0
8
0
Order By: Relevance
“…2,21 The underlying cause of early failure is generally attributed to insufficient initial stability of the interface. 16 Because the initial stability of UN THA depends primarily on fixation between the prosthesis and bone, selection of suitable patients is needed, in combination with the use of an appropriate prosthesis and effective surgical techniques. 6,11 Following changes in prosthesis design and surface coating technology, short-term and medium-term success of UN THA have led to wide acceptance among clinicians.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…2,21 The underlying cause of early failure is generally attributed to insufficient initial stability of the interface. 16 Because the initial stability of UN THA depends primarily on fixation between the prosthesis and bone, selection of suitable patients is needed, in combination with the use of an appropriate prosthesis and effective surgical techniques. 6,11 Following changes in prosthesis design and surface coating technology, short-term and medium-term success of UN THA have led to wide acceptance among clinicians.…”
Section: Discussionmentioning
confidence: 99%
“…Since the development of artificial joints, controversy regarding CE vs. UN femoral components in THA has been an important issue in the field of prosthesis replacement. 16 The principles of CE fixation and low friction associated with metal-polyethylene have been important in the development of modern THA. 3 Mechanical stability of the interface is achieved through bulk filling of bone cement between the prosthesis and bone, as well as by microscopic interlocking.…”
Section: Discussionmentioning
confidence: 99%
“…4,5,[13][14][15][16][17] In the study conducted by Wang et al, the 5-year survival rates of the cemented and cementless stems were 88.2% and 91.3%, respectively. 18 Bone grafts are utilized frequently in revision hip arthroplasty to compensate for present bone loss. Bone grafts serve two purposes, including mechanical support and osteogenesis.…”
Section: Discussionmentioning
confidence: 99%
“…4,5,13 17 In the study conducted by Wang et al, the 5-year survival rates of the cemented and cementless stems were 88.2% and 91.3%, respectively. 18…”
Section: Discussionmentioning
confidence: 99%
“…The reasons to exclude a cemented stem as the first-line treatment option at our institution included bone-cement implantation syndrome during implanting a cemented stem 27 and technical challenges and complications during the rerevision procedure of a well-fixed cemented stem, including massive bone loss, cortical perforation, or fracture. 28,29 Cementless femoral stems were considered first in all revision hip arthroplasty procedures, except for patients with severe osteoporosis. Because of the relatively small sample size (N = 13), we excluded the use of cemented stem from our analysis.…”
Section: Methodsmentioning
confidence: 99%