2020
DOI: 10.1016/j.peptides.2019.170249
|View full text |Cite
|
Sign up to set email alerts
|

Melanin-concentrating hormone (MCH) in the median raphe nucleus: Fibers, receptors and cellular effects

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
9
0

Year Published

2021
2021
2023
2023

Publication Types

Select...
5
1

Relationship

2
4

Authors

Journals

citations
Cited by 10 publications
(9 citation statements)
references
References 38 publications
0
9
0
Order By: Relevance
“…Single unit activity in the mPOA was acquired and processed using Spike2 software (Cambridge Electronic Design, UK). Baseline firing of mPOA units was recorded for at least 300 s. Afterward, juxta-cellular HCRT-1 (100 μM, BACHEM, Bubendorf, Switzerland) diluted in sterile saline 0.9 % (or its vehicle) was applied by pressure pulses of 20 PSI for 200 to 300 ms (Devera et al, 2015; Pascovich et al, 2020). EEG signals were amplified (x1000), filtered (0.1–500 Hz), sampled (1024 Hz, 16 bits), acquired, and processed using the Spike2 software.…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…Single unit activity in the mPOA was acquired and processed using Spike2 software (Cambridge Electronic Design, UK). Baseline firing of mPOA units was recorded for at least 300 s. Afterward, juxta-cellular HCRT-1 (100 μM, BACHEM, Bubendorf, Switzerland) diluted in sterile saline 0.9 % (or its vehicle) was applied by pressure pulses of 20 PSI for 200 to 300 ms (Devera et al, 2015; Pascovich et al, 2020). EEG signals were amplified (x1000), filtered (0.1–500 Hz), sampled (1024 Hz, 16 bits), acquired, and processed using the Spike2 software.…”
Section: Methodsmentioning
confidence: 99%
“…We used the Mann–Whitney test to compare the firing rate of each neuron during NREMure vs. REMure (windows of 1 to 5 minutes depending on the firing rate of the analyzed neurons). We also compared the firing rate before and after HCRT-1 administration with the same approach (Torterolo et al, 2002; Cabrera et al, 2013; Devera et al, 2015; Pascovich et al, 2020). The population mean between these conditions was analyzed using the Wilcoxon Signed-Rank Test.…”
Section: Methodsmentioning
confidence: 99%
“…Intracerebroventricular (ICV) injection of MCH peptide in rats resulted in increased time in both non-REM and REM sleep ( Verret et al, 2003 ). More targeted injections into the locus coeruleus (LC) or raphe nuclei led to increases in REM sleep ( Lagos et al, 2009 , 2011a ; Monti et al, 2015 ; Devera et al, 2015 , 2021 ; Pascovich et al, 2020 , 2021 ), likely through actions on noradrenergic and serotonergic neurons, respectively (see below). Microinjection of MCH into the VLPO, a region implicated in generating NREM sleep, selectively enhanced NREM sleep without affecting REM sleep – however, the physiological relevance of this finding is questionable, given the lack of effect on NREM sleep observed in most subsequent studies of the MCH system ( Benedetto et al, 2013 ).…”
Section: The Role Of the Melanin-concentrating Hormone System In Sleepmentioning
confidence: 99%
“…We carried out unit recordings using standard procedures with an Ag-Cl electrode inside a glass micropipette of 5-20 MΩ, filled with 2M NaCl; we also handmade fabricated double micropipettes for simultaneous recording and juxta-cellular administration of HCRT (Torterolo et al, 1998;Torterolo et al, 2002;Devera et al, 2015;Pascovich et al, 2020). An Ag-Cl electrode under the neck skin was used as reference for unit recordings.…”
Section: Unit and Eeg Recordingsmentioning
confidence: 99%
“…Baseline firing of mPOA units was recorded for at least 300 s. Afterward, juxta-cellular HCRT-1 (100 µM, BACHEM, Bubendorf, Switzerland) diluted in sterile saline 0.9 % (or its vehicle) was applied by pressure pulses of 20 PSI for 200 to 300 ms (Devera et al, 2015;Pascovich et al, 2020). EEG signals were amplified (x1000), filtered (0.1-500 Hz), sampled (1024 Hz, 16 bits), acquired, and processed using the Spike2 software.…”
Section: Unit and Eeg Recordingsmentioning
confidence: 99%