2005
DOI: 10.1205/cherd.04196
|View full text |Cite
|
Sign up to set email alerts
|

Membrane Contactors in Industrial Applications

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
58
0
5

Year Published

2013
2013
2021
2021

Publication Types

Select...
5
2
1

Relationship

0
8

Authors

Journals

citations
Cited by 149 publications
(63 citation statements)
references
References 12 publications
0
58
0
5
Order By: Relevance
“…Membrane gas absorption is a novel method with high efficiency, less required energy and low costs relative to conventional absorption methods (Feron and Jansen, 1997;Hoff, 2003). Furthermore, the hollow fiber membrane contactor (HFMC) has attracted the attention of researchers for the advantages of high-performance absorption, small volume and lightweight (Klaassen, 2005). This paper focuses on the recent progress of the membrane gas absorption of CO 2 .…”
Section: Introductionmentioning
confidence: 99%
“…Membrane gas absorption is a novel method with high efficiency, less required energy and low costs relative to conventional absorption methods (Feron and Jansen, 1997;Hoff, 2003). Furthermore, the hollow fiber membrane contactor (HFMC) has attracted the attention of researchers for the advantages of high-performance absorption, small volume and lightweight (Klaassen, 2005). This paper focuses on the recent progress of the membrane gas absorption of CO 2 .…”
Section: Introductionmentioning
confidence: 99%
“…Nevertheless, it can be noted that a comparison of the proposed technology with the conventional gas absorption towers is in favor of membrane technology when substantial benefits are expected by the much smaller volume and high flexibility of membrane contactors relative to packed columns, since the use of a membrane absorber can lead to a tenfold reduction in equipment size [11,14]. However, it is often pointed out in the literature that the price of the membranes must be reduced and their reliability must be increased to displace the well-established technologies [16,17].…”
Section: Resultsmentioning
confidence: 99%
“…To the best of our knowledge, there are very few experiments conducted in real industrial environments, published in the open literature. Probably, the most prominent exception is the work conducted from the TNO group, who installed a membrane gas absorption pilot unit and studied CO 2 capture from real flue gases, coming from a gas fired pilot plant [14].…”
Section: Introductionmentioning
confidence: 99%
“…Thus, membrane contactor operations can be designed with the same phenomenological approach of conventional extraction or absorption processes [1].…”
Section: Introductionmentioning
confidence: 99%
“…However, the design of a membrane absorber cannot be based on the same hollow fiber modules used in filtration processes, which respond to other design criteria. Figure 1 shows an outline of three different arrangements of hollow fiber modules [1,2].…”
Section: Introductionmentioning
confidence: 99%