Abstract:A platinum wire with a diameter of 20 µm and length of 14 mm was attached to the surface of a ceramic membrane for in situ fouling monitoring. By measuring the voltage across the wire while applying an AC current, the amplitude of the third harmonic wave, the so-called 3ω signal, which is inversely proportional to the thermal conductivity around the wire, was obtained. It was demonstrated that the 3ω signal is influenced by changing the environment around the wire as a result of differences in thermal conducti… Show more
Set email alert for when this publication receives citations?
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.