Abstract:European legislation has set a limit of 5 mg Hg per compact fluorescent lamp (CFL). Compliance with this regulation is tested with a method given in a European law from 2002 ("EU method"). According to the EU method, the arc tube has to be placed inside a fume cupboard and cut into segments. These pieces are collected and washed with HNO3, which is finally analyzed for Hg. In this study, we investigated the losses of Hg via the gas phase, which are ignored by the EU method, using a semiquantitative radiochemic… Show more
Set email alert for when this publication receives citations?
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.