1976
DOI: 10.1007/bf02584516
|View full text |Cite
|
Sign up to set email alerts
|

Mercury-in-rubber (whitney) strain gauge

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
5
0

Year Published

1980
1980
2017
2017

Publication Types

Select...
2
2
2

Relationship

0
6

Authors

Journals

citations
Cited by 9 publications
(5 citation statements)
references
References 3 publications
0
5
0
Order By: Relevance
“…[49,50] Mercury-based strain sensors were investigated in the 1980s; [51][52][53][54][55] however,asan ontoxic alternative to mercury,EGaIn and Galinstan have recently been investigated. They include mercury,eutectic gallium-indium alloy (EGaIn),a nd gallium-indium-tin alloy (Galinstan).…”
Section: Liquid-metal-in-rubberstrain Sensorsmentioning
confidence: 99%
See 1 more Smart Citation
“…[49,50] Mercury-based strain sensors were investigated in the 1980s; [51][52][53][54][55] however,asan ontoxic alternative to mercury,EGaIn and Galinstan have recently been investigated. They include mercury,eutectic gallium-indium alloy (EGaIn),a nd gallium-indium-tin alloy (Galinstan).…”
Section: Liquid-metal-in-rubberstrain Sensorsmentioning
confidence: 99%
“…Such liquid metals have gained significant interest because of their high electrical conductivity (1.0 10 6 for Hg and 3.4 10 6 Sm À1 for gallium-indium alloys) and extreme stretchability (e > 600 %) withoutc onductivity loss. [49,50] Mercury-based strain sensors were investigated in the 1980s; [51][52][53][54][55] however,asan ontoxic alternative to mercury,EGaIn and Galinstan have recently been investigated. [50,[56][57][58][59][60][61][62][63][64][65][66][67][68][69][70] Whitesides et al have demonstrated a3 Ds tructure of EGaIn by filling microfluidic channels fabricated in as ilicon rubber.…”
Section: Liquid-metal-in-rubberstrain Sensorsmentioning
confidence: 99%
“…The strain sensors have a wide working voltage range, even up to 1V [9]. Besides the demonstrated function of large displacement strain sensors in limb pethysmography [1,11,12,13] and penile circumference measurements [2,14], other applications include pneumography [15] and the measurement of tendon strain in the knee or glenohumeral joint [16], as well as the monitoring of displacement of soft robotic grippers, pneumatic and hydraulic actuators [17].…”
Section: Introductionmentioning
confidence: 99%
“…A variety of methodologies exist for the measurement of strain [72,73]. However, many of these techniques require maintained physical contact with the material being measured [72,73].…”
Section: Strain Analysis Techniquesmentioning
confidence: 99%
“…A variety of methodologies exist for the measurement of strain [72,73]. However, many of these techniques require maintained physical contact with the material being measured [72,73]. As the goal of these headforms is to provide a response that is adequately representative of brain tissue strain, the material under investigation would likely be a highly deformable elastomer.…”
Section: Strain Analysis Techniquesmentioning