2023
DOI: 10.1039/d3ce00324h
|View full text |Cite
|
Sign up to set email alerts
|

Mesoscale clusters in multicomponent systems: the effect of solution preparation and pre-treatment on primary nucleation of a carbamazepine-saccharin cocrystal

Jordan Crutzen,
Lai Zeng,
Michael Svärd

Abstract: In this work, direct investigation of mesoscale clusters in solution using dynamic light scattering is combined with an indirect method based on the study of primary crystal nucleation and its...

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
18
0

Year Published

2023
2023
2025
2025

Publication Types

Select...
4

Relationship

2
2

Authors

Journals

citations
Cited by 4 publications
(18 citation statements)
references
References 49 publications
0
18
0
Order By: Relevance
“…Liquid light scattering techniques have been used for gaining understanding of the cluster stability primarily due to its short analysis time. Contrasting results have been obtained where some reports have indicated mesoscale clusters to be stable [18,31] while others have reported them to be metastable [21,29] . In the case of OTBN‐methanol and chloroform solutions, the size of clusters remained stable for several days in the absence of agitation as measured by DLS and NTA [31] .…”
Section: Critical Cluster Propertiesmentioning
confidence: 79%
See 4 more Smart Citations
“…Liquid light scattering techniques have been used for gaining understanding of the cluster stability primarily due to its short analysis time. Contrasting results have been obtained where some reports have indicated mesoscale clusters to be stable [18,31] while others have reported them to be metastable [21,29] . In the case of OTBN‐methanol and chloroform solutions, the size of clusters remained stable for several days in the absence of agitation as measured by DLS and NTA [31] .…”
Section: Critical Cluster Propertiesmentioning
confidence: 79%
“…for fenoxycarb‐isopropanol (IPA) solutions [29] . They observed a significant decrease in mesoscale cluster concentration (Figure 6C) measured with NTA after incubation at 40 °C compared to freshly dissolved solutions and solutions exposed to near ambient conditions (22 °C) [29] …”
Section: Critical Cluster Propertiesmentioning
confidence: 94%
See 3 more Smart Citations