Metal-as-Insulation REBCO Insert: Simplified Protection Scheme and Investigation of Cooling Defect Under High-Field Operation

Jung-Bin Song,
Xavier Chaud,
François Debray
et al.

Abstract: A refurbished metal-as-insulation (MI) HTS insert comprised of DP coils with replaced inner joints was charged under various magnetic field (Bext) from 0 to 18 T at 4.2 K for testing. However, the refurbished insert could not be charged up to its maximum field, because the cryogenic condition tended to be unstable with a high helium boiling rate above 28 T. Therefore, to investigate the cooling issue, four Cernox sensors were installed in refurbished insert. The temperature of each position while powering the … Show more