2006
DOI: 10.1016/j.talanta.2005.11.051
|View full text |Cite
|
Sign up to set email alerts
|

Method development for the analysis of polybrominated diphenyl ethers, polychlorinated biphenyls, polychlorinated dibenzo-p-dioxins and dibenzo-furans in single extract of sediment samples

Abstract: A comprehensive method was developed for quantitative analysis of polybrominated diphenyl ethers (PBDEs), polychlorinated biphenyls (PCBs) and polychlorinated dibenzo-p-dioxins and dibenzo-furans (PCDD/Fs) in one single extract of environmental samples. The sample preparation procedure included two fractionation steps using silver nitrate silica chromatography to separate PBDEs from PCBs and PCDD/Fs and florisil column to separate PCBs from PCDD/Fs. Acidic silica, acidic alumina and gel permeation chromatograp… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...

Citation Types

0
1
0

Year Published

2007
2007
2013
2013

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 13 publications
(1 citation statement)
references
References 14 publications
0
1
0
Order By: Relevance
“…However, GC/MS is preferred now because absolute chromatographic separation for the individual analyte was difficult even if multidimensional GC was employed [10]. Several GC/MS methods have been established based on high-resolution magnetic-sector MS (HR-MS) [11], tandem MS (MS/MS) using an ion trap detector [12][13][14], or triple quadrupole analyzer [15] and time-of-flight MS (TOF-MS) [16], as well as lowresolution quadrupole MS (qMS) [17]. Obviously, HR-MS is the most powerful tool offering high selectivity with satisfactory sensitivity by virtue of its high ultimate resolving power and accurate mass measurement; nevertheless, nowadays only a few laboratories can afford this instrument.…”
mentioning
confidence: 99%
“…However, GC/MS is preferred now because absolute chromatographic separation for the individual analyte was difficult even if multidimensional GC was employed [10]. Several GC/MS methods have been established based on high-resolution magnetic-sector MS (HR-MS) [11], tandem MS (MS/MS) using an ion trap detector [12][13][14], or triple quadrupole analyzer [15] and time-of-flight MS (TOF-MS) [16], as well as lowresolution quadrupole MS (qMS) [17]. Obviously, HR-MS is the most powerful tool offering high selectivity with satisfactory sensitivity by virtue of its high ultimate resolving power and accurate mass measurement; nevertheless, nowadays only a few laboratories can afford this instrument.…”
mentioning
confidence: 99%