1999
DOI: 10.1016/s0022-3913(99)80005-5
|View full text |Cite
|
Sign up to set email alerts
|

Method for enhancing retention in complete denture bases

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

0
15
0

Year Published

2000
2000
2024
2024

Publication Types

Select...
9

Relationship

0
9

Authors

Journals

citations
Cited by 20 publications
(15 citation statements)
references
References 17 publications
0
15
0
Order By: Relevance
“…Many authors (6-8) consider these products to improve denture stability and retention, though almost all the research published in the literature consists of in vitro studies (9) and/or is based on the administration of patient satisfaction questionnaires (10,11). Of the limited in vivo studies carried out to date, most involve the upper maxilla (12), and only a few involve the mandible (13). We therefore designed the present study to compare the efficacy of these products in the course of several hours of use.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…Many authors (6-8) consider these products to improve denture stability and retention, though almost all the research published in the literature consists of in vitro studies (9) and/or is based on the administration of patient satisfaction questionnaires (10,11). Of the limited in vivo studies carried out to date, most involve the upper maxilla (12), and only a few involve the mandible (13). We therefore designed the present study to compare the efficacy of these products in the course of several hours of use.…”
Section: Discussionmentioning
confidence: 99%
“…One of the problems associated with studies of this kind is the need for a system capable of registering retention, with simple handling characteristics and good patient tolerance (12)(13)(14). In this study we used a very simple spring scale that proved comfortable for the patients.…”
Section: Discussionmentioning
confidence: 99%
“…The devices used by previous investigators include: spring balances 16 , lever arm with loading apparatus 17,18 , Rhiele universal testing machine 19 , dial type push pull dynamometer 20 , strain gauge force transducer 21,22 and hydraulic and electronic system using an extra oral transducer. Digital force gauge (Lutron FG 5000 A) with 3 types of display units: gram, Newton and ounce was used in this study.…”
Section: Discussion:-mentioning
confidence: 99%
“…The contact calculation algorithm assumed that the denture lost adherence to the foundation when there were no negative interfacial normsd stresses. The low adhesive forces [12] that were omitted in the contact calculation play a secondary role during denture destabilization under higher mastication forces. The model was prepared using computer aided design software in a way that made it possible to achieve a coherent mesh at the contact zone with hexahedral elements.…”
Section: Methodsmentioning
confidence: 99%