2002
DOI: 10.1016/s0003-2670(02)00872-3
|View full text |Cite
|
Sign up to set email alerts
|

Method for monitoring urea and ammonia in wine and must by flow injection–pervaporation

Abstract: An easy to automate flow-injection-pervaporation method for monitoring urea and ammonia in must and wine was developed. The method is based on separation of the ammonia from the sample matrix by pervaporation followed by its reaction with salicylate, hypochlorite and nitroprusside to form a diazonium salt with maximum absorption at 647 nm. Conversion of urea into ammonia catalysed by urease was mandatory before pervaporation. After optimisation by either the univariate or multivariate approaches as required, t… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
7
0
1

Year Published

2003
2003
2021
2021

Publication Types

Select...
7
2

Relationship

0
9

Authors

Journals

citations
Cited by 21 publications
(9 citation statements)
references
References 12 publications
1
7
0
1
Order By: Relevance
“…A rectilinear calibration graph was obtained for the range 0.2-4 mg L −1 of ammonia; correlation coefficient and LOD were found to be 0.9985 and 46 g L −1 of ammonia, respectively. This sensitivity compared better than the literature values, 100 g L −1 by indicators colour change in FIA [80], 600 g L −1 by indophenol formation in FIA [81], 300 g L −1 by gas-diffusion and indophenol formation [82], 770 g L −1 by gasdiffusion and indicator colour change [83], 500 g L −1 by indicator colour change in SIA [84], and 70 g L −1 by multi-syringe FIA [85].…”
Section: Ammoniasupporting
confidence: 39%
“…A rectilinear calibration graph was obtained for the range 0.2-4 mg L −1 of ammonia; correlation coefficient and LOD were found to be 0.9985 and 46 g L −1 of ammonia, respectively. This sensitivity compared better than the literature values, 100 g L −1 by indicators colour change in FIA [80], 600 g L −1 by indophenol formation in FIA [81], 300 g L −1 by gas-diffusion and indophenol formation [82], 770 g L −1 by gasdiffusion and indicator colour change [83], 500 g L −1 by indicator colour change in SIA [84], and 70 g L −1 by multi-syringe FIA [85].…”
Section: Ammoniasupporting
confidence: 39%
“…Various examples of pervaporation flow injection (PFI) in food quality control have been reported including the determination of sulphide in Kraft liquors (Papaefstathiou, Luque de Castro, & Valcarcel, 1996), sulphur dioxide in wines (Mataix & Luque de Castro, 1998), diacetyl (Izquierdo-Ferrero, Romero, & Luque de Castro, 1997), urea (Gonzalez-Rodroguez, Perez-Juan, & Luque de Castro, 2002a, 2002b, ammonia in beers (Wang, Cardwell, Cattrall, Luque de Castro, & Kolev, 2003), and methanol and iron combined in vinegar (Gonzalez-Rodroguez et al, 2002a, 2002b. These are testaments to its versatility and robustness.…”
Section: Introductionmentioning
confidence: 99%
“…Single or several parameters have been determined in wines after pervaporation, namely: volatile and total acidity [3], ethanol and glycerol [15], free and total sulfur dioxide [16], carbon dioxide and free sulfur dioxide [17], methanol, ethanol, ethyl acetate and acetaldehyde [18], urea and ammonia [19]. The appropriate flow-injection (FI) manifold and detector, together with the pervaporator, made the experimental setup in each case.…”
Section: Introductionmentioning
confidence: 99%