2020
DOI: 10.1007/s00216-020-02702-9
|View full text |Cite
|
Sign up to set email alerts
|

Method for the elucidation of LAMP products captured on lateral flow strips in a point of care test for HPV 16

Abstract: Loop-mediated amplification (LAMP) is an isothermal amplification technique favored in diagnostics and point-of-care work due to its high sensitivity and ability to run in isothermal conditions. In addition, a visual readout by lateral flow strips (LFS) can be used in conjunction with LAMP, making the assay accessible at the point-of-care. However, the amplicons resulting from a LAMP reaction varied in length and shape, making them undiscernible on a double-stranded DNA intercalating dye stained gel. Standard … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
23
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
8

Relationship

1
7

Authors

Journals

citations
Cited by 12 publications
(23 citation statements)
references
References 22 publications
0
23
0
Order By: Relevance
“…There have been many efforts to reduce LAMP false-positives caused by nonspecific amplification. These include using fluorescently tagged primers to minimize false-positives, 45 , 46 mathematical modeling to predict desired LAMP amplicon sizes, 47 and the inclusion of dimethyl sulfoxide (DMSO) in the amplification. 48 , 49 DMSO is a hazardous chemical, and its application in a LAMP reaction requires significant optimization.…”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…There have been many efforts to reduce LAMP false-positives caused by nonspecific amplification. These include using fluorescently tagged primers to minimize false-positives, 45 , 46 mathematical modeling to predict desired LAMP amplicon sizes, 47 and the inclusion of dimethyl sulfoxide (DMSO) in the amplification. 48 , 49 DMSO is a hazardous chemical, and its application in a LAMP reaction requires significant optimization.…”
Section: Resultsmentioning
confidence: 99%
“…The BD SurePath samples were prepared as previously reported. 46 In short, clinical samples were taken from the container and aliquoted into 1.7-mL tubes. In order to pellet the sample, all tubes were spun down at 13 000 rpm.…”
Section: Materials and Methodsmentioning
confidence: 99%
“…Results demonstrated the expected wide distribution of fragment sizes as described by others. 1,2,17,18 Qubit quantification of Qiagen-purified amplicon product exceeded 6 mg total, whereas NTCs were below 100-300 ng (data not shown).…”
Section: T a B L Ementioning
confidence: 94%
“…The polymerase chain reaction (PCR) is one of the most commonly used methods in clinical practice, which can amplify a target sequence more than a million times in a brief period and requires small sample volumes [ 3 ]. Other available techniques include the rolling circle amplification reaction (RCA) [ 4 , 5 ], the hybridisation chain reaction (HCR) [ 6 ], and loop-mediated isothermal amplification (LAMP) [ 7 , 8 , 9 ]. However, these techniques present a series of limitations.…”
Section: Introductionmentioning
confidence: 99%