Abstract:Demand has increased for the double-sided moulding of microfluidic devices for a series of biochemical analyses. Accurate alignment of mould inserts is a critical aspect to transfer doubled-sided patterns on the top and bottom surfaces of a moulded part. A method of mould alignment was studied for double-sided hot embossing of polymer microfluidic devices. An alignment method was designed using kinematic constraints, and a set of three locating pins. To validate the alignment method, two brass mould inserts wi… Show more
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.