Method of symmetrical co-ordinates applied to the solution of polyphase networks

Abstract: OF PAPER In the introduction a general discussion of unsymmetrical systems of co-planar vectors leads to the conclusion that they may be represented by symmetrical systems of the same number of vectors, the number of symmetrical systems required to define the given system being equal to its degrees of freedom. A few trigonometrical theorems which are to be used in the paper are called to mind. The paper is subdivided into three parts, an abstract of which follows. It is recommended that only that part of Part … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
81
0
16

Year Published

1993
1993
2021
2021

Publication Types

Select...
8
1

Relationship

0
9

Authors

Journals

citations
Cited by 96 publications
(97 citation statements)
references
References 0 publications
0
81
0
16
Order By: Relevance
“…We consider a system where the grid voltage is composed of positive and negative sequence voltages during unbalance. The unbalance factor (β) represents the ratio of the amplitude of the negative to the positive sequence voltages in the circuit [32] [33]. It is considered that the converter is controlled to inject negative sequence voltage proportionate to that in the grid to avoid the circulation of negative sequence current.…”
Section: Converter Operation During Grid Voltage Unbalancementioning
confidence: 99%
“…We consider a system where the grid voltage is composed of positive and negative sequence voltages during unbalance. The unbalance factor (β) represents the ratio of the amplitude of the negative to the positive sequence voltages in the circuit [32] [33]. It is considered that the converter is controlled to inject negative sequence voltage proportionate to that in the grid to avoid the circulation of negative sequence current.…”
Section: Converter Operation During Grid Voltage Unbalancementioning
confidence: 99%
“…The method was originally presented by C.L. Fortescue in 1918 and has been popular ever since [41][42]. Figure 5 shows the equivalent sequence circuits of a transmission line AB whose impedance is Z AB .…”
Section: Phase To Ground Fault Calculations In the Presence Of Facts mentioning
confidence: 99%
“…In order to obtain the phase voltages at the fault point in the presence of FACTS device and fault resistance, the following equation is used, [41][42]:…”
Section: Phase To Ground Fault Calculations In the Presence Of Facts mentioning
confidence: 99%
“…The positive, negative and zero-sequence components of the primary winding currents ( ̅ , ̅ , ̅ ) are obtained from Fortescue's theorem [14]. There are no zero-sequence components in the primary winding currents ( ̅ 0), and the same occurs with the set of secondary currents ( ̅ ̅ , ̅ , ̅ ), whose symmetrical components ( ̅ , ̅ , ̅ ) are the primary symmetrical components multiplied by the transformation ratio ( ), according to Equation (8); thus, ̅ 0.…”
Section: High Voltage (Hv) Line and Transformer Voltages Currents Anmentioning
confidence: 99%