2005
DOI: 10.1016/j.ijmultiphaseflow.2005.02.003
|View full text |Cite
|
Sign up to set email alerts
|

Methodological improvement of an intrusive four-sensor probe for the multi-dimensional two-phase flow measurement

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
36
0
1

Year Published

2013
2013
2022
2022

Publication Types

Select...
7
1
1

Relationship

2
7

Authors

Journals

citations
Cited by 71 publications
(37 citation statements)
references
References 10 publications
0
36
0
1
Order By: Relevance
“…The existing literature for needle probe sensors (Kataoka et al, 1986;Kataoka and Serizawa, 1990;Revankar and Ishii, 1992;Kalkach-Navarro et al, 1993;Cartellier, 1999;Dias et al, 2000;Fu, 2001;Wu et al, 2001;Kim et al, 2001;Euh et al, 2001;Shen et al, 2005;Pradhan et al, 2013) is employed to measure the local two-phase flow parameters in the present work. The four-sensor conductivity probe design used in the present experiments is based in the previous work of (Kim et al, 2001) and consisted of 4 enamelled copper wires (0.2 mm outer diameter).…”
Section: Four-sensor Probe Methodologymentioning
confidence: 99%
See 1 more Smart Citation
“…The existing literature for needle probe sensors (Kataoka et al, 1986;Kataoka and Serizawa, 1990;Revankar and Ishii, 1992;Kalkach-Navarro et al, 1993;Cartellier, 1999;Dias et al, 2000;Fu, 2001;Wu et al, 2001;Kim et al, 2001;Euh et al, 2001;Shen et al, 2005;Pradhan et al, 2013) is employed to measure the local two-phase flow parameters in the present work. The four-sensor conductivity probe design used in the present experiments is based in the previous work of (Kim et al, 2001) and consisted of 4 enamelled copper wires (0.2 mm outer diameter).…”
Section: Four-sensor Probe Methodologymentioning
confidence: 99%
“…From the pioneer work of (Kataoka et al, 1986) on the local interfacial area derivation from velocity measurements, (Kim et al, 2001) proposed a miniaturized probe and made it capable of measuring both large and small bubbles. (Shen et al, 2005) and (Shen and Nakamura, 2013) proposed an explicit equation for the instantaneous local interfacial area and local interfacial velocity using four sensor conductivity probes, which take into account both receding and oncoming interfaces. Then, local values of IAC can be calculated as:…”
Section: C) Interfacial Area Concentrationmentioning
confidence: 99%
“…In order to further verify the accuracy of the void fraction measurements by the differential pressure gauges, we compared them with local void fraction measurements by the optical multi-sensor probe method (Shen et al, 2005b, 2008a, 2008band Shen and Nakamura, 2013 and the X-type hot-film probe method (Bruun, 1995). The measurement errors in both comparisons are within ±10%.…”
Section: Experimental Conditions and Measurement Verificationmentioning
confidence: 99%
“…a flat-tip type probe [33,34] was used to measure the bubble diameter profiles along the diagonal, x-bisector and x-wall-nearest line (see Figure 3) in the same two-phase flow conditions at z/D H = 16.1. The optical probe was traversed by the same traversing device as the hot-film anemometry.…”
Section: Experimental Apparatusmentioning
confidence: 99%