Methods for Noise Event Detection and Assessment of the Sonic Environment by the Harmonica Index

Abstract: Noise annoyance depends not only on sound energy, but also on other features, such as those in its spectrum (e.g., low frequency and/or tonal components), and, over time, amplitude fluctuations, such as those observed in road, rail, or aircraft noise passages. The larger these fluctuations, the more annoying a sound is generally perceived. Many algorithms have been implemented to quantify these fluctuations and identify noise events, either by looking at transients in the sound level time history, such as exce… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
7
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 7 publications
(7 citation statements)
references
References 19 publications
0
7
0
Order By: Relevance
“…However, recent research [7][8][9][10] has proposed new indicators and algorithms to assess noise disturbance. They consider not only sound energy, but also noise variations, such as the Intermittency Ratio (IR) indicator, or other noise features, such as those in its spectrumthe Harmonica index and its applications.…”
Section: Introductionmentioning
confidence: 99%
“…However, recent research [7][8][9][10] has proposed new indicators and algorithms to assess noise disturbance. They consider not only sound energy, but also noise variations, such as the Intermittency Ratio (IR) indicator, or other noise features, such as those in its spectrumthe Harmonica index and its applications.…”
Section: Introductionmentioning
confidence: 99%
“…That the pass-by sounds have a large possibility to be audible is further substantiated by the coherence with recent work where detection of events assumes that they are 3 dB above the equivalent level. 7,20…”
Section: Resultsmentioning
confidence: 99%
“…That the pass-by sounds have a large possibility to be audible is further substantiated by the coherence with recent work where detection of events assumes that they are 3 dB above the equivalent level. 7,20 The two curves that at 160 and 200 Hz show an indoor maximum level clearly above the Public Health Agency's curve are calculated for a normal window, with ordinary but not poor sound insulation. This window can thus provide audible passages even at the upper part of the low-frequency range.…”
Section: Possible Audibility Of Individual Pass-by Eventsmentioning
confidence: 99%
“…The time history of the LAeq was aggregated in 15-min intervals to fit the resolution of the actigraph used for patient rest/activity monitoring. The equivalent background noise level (LA95eq), evaluated every second by the noise level exceeded 95% of the time during the previous T /6 interval, where T is the measurement time, was estimated according to Alsina-Pagès et al (2021). The intermittency ratio (IR) was computed as in Wunderli et al (2016).…”
Section: Methodsmentioning
confidence: 99%