1967
DOI: 10.1016/b978-1-4831-9988-7.50009-3
|View full text |Cite
|
Sign up to set email alerts
|

Methods for the Determination of Carbon Monoxide

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
5
0

Year Published

1969
1969
2019
2019

Publication Types

Select...
5
1

Relationship

0
6

Authors

Journals

citations
Cited by 6 publications
(5 citation statements)
references
References 9 publications
0
5
0
Order By: Relevance
“…In addition to microdi¡usion, there are numerous other methods, which rely on reacting liberated carbon monoxide with a colour reagent, and some are claimed to be capable of measuring endogenous saturation levels as low as 1%. For example, in one method 33 the liberated gas mixed with air is led into a £ask containing an alkaline solution of the silver salt of p-sulphaminobenzoic acid which generates a colloidal solution of silver. The absorbance of this solution is related to the carbon monoxide concentration in the gas sample.…”
Section: Colorimetric Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…In addition to microdi¡usion, there are numerous other methods, which rely on reacting liberated carbon monoxide with a colour reagent, and some are claimed to be capable of measuring endogenous saturation levels as low as 1%. For example, in one method 33 the liberated gas mixed with air is led into a £ask containing an alkaline solution of the silver salt of p-sulphaminobenzoic acid which generates a colloidal solution of silver. The absorbance of this solution is related to the carbon monoxide concentration in the gas sample.…”
Section: Colorimetric Methodsmentioning
confidence: 99%
“…For example, in one method 33 the liberated gas mixed with air is led into a £ask containing an alkaline solution of the silver salt of p-sulphaminobenzoic acid which generates a colloidal solution of silver. The absorbance of this solution is related to the carbon monoxide concentration in the gas sample.…”
Section: Colorimetric Methodsmentioning
confidence: 99%
“…Carbon monoxide measured by using multi sensor is an automatic and uninterrupted system, it works based on the absorption of infrared radiation by the CO molecule (Feldstein, 1967). This multi-gas analyser incorporated with a selective gas filter to eliminate or reduce the interference raised from other gases like carbon dioxide, water vapour, oxides of nitrogen and sulphur.…”
Section: Carbon Monoxidementioning
confidence: 99%
“…Previously described methods for CO measurement include microdiffusion, colorimetric, infrared absorption, volumetric or spectrophotometric methods (Feldstein, 1967). Other investigators have use manometric oxidation, microcalorimetric or indirect methods (Commins, 1975).…”
Section: Analytical Methods For the Analysis Of Carbon Monoxidementioning
confidence: 99%