Search citation statements
Paper Sections
Citation Types
Year Published
Publication Types
Relationship
Authors
Journals
Background. Paired-pulse transcranial magnetic stimulation allows assessing intracortical inhibition. However, a high variability of motor evoked potential (MEP) amplitude is a limitation of its use. Therefore, a new threshold tracking technique became of particular interest, which is based on the measurement not of the amplitude, but of the change of test stimulus intensity required to induce a MEP of a given amplitude.Aim. The assessment of absolute and relative reliability of short-interval intracortical inhibition (SICI) using threshold tracking technique in healthy volunteers.Materials and methods. All healthy volunteers included into the study (n = 12) underwent diagnostic paired-pulse transcranial magnetic stimulation in two consecutive days. The procedure included registration of passive motor threshold; the registration of 30 MEPs with supra-threshold intensity and determination of SICI using threshold tracking technique. At the first day the procedure was performed twice (T1, T2), at the second day – once (T3). Standard error of the measurement (SEM) and SEM% were calculated to assess absolute reliability, and intra-class correlation coefficient – for the assessment of relative reliability.Results. A good or excellent relative reliability were observed for SICI averaged at intervals 1.0–3.0 ms and 1.0–7.0 ms when assessed within a day or at different days. Relative reliability of SICI at separate interstimulus intervals varied in a wide range. SEM% was more than 10 % both for averaged SICI and SICI at all interstimulus intervals. Motor threshold had excellent reliability both assessed within a day and at different days, and low SEM values (5.6 % for Т1–Т2 and 4.39 % for Т1–Т3). High SEM and SEM% were observed for average MEP amplitude, it also had a moderate relative reliability when assessed within a day and a poor one – at different days.Conclusion. Calculation of averaged SICI can be recommended in further studies because of its high reliability values.
Background. Paired-pulse transcranial magnetic stimulation allows assessing intracortical inhibition. However, a high variability of motor evoked potential (MEP) amplitude is a limitation of its use. Therefore, a new threshold tracking technique became of particular interest, which is based on the measurement not of the amplitude, but of the change of test stimulus intensity required to induce a MEP of a given amplitude.Aim. The assessment of absolute and relative reliability of short-interval intracortical inhibition (SICI) using threshold tracking technique in healthy volunteers.Materials and methods. All healthy volunteers included into the study (n = 12) underwent diagnostic paired-pulse transcranial magnetic stimulation in two consecutive days. The procedure included registration of passive motor threshold; the registration of 30 MEPs with supra-threshold intensity and determination of SICI using threshold tracking technique. At the first day the procedure was performed twice (T1, T2), at the second day – once (T3). Standard error of the measurement (SEM) and SEM% were calculated to assess absolute reliability, and intra-class correlation coefficient – for the assessment of relative reliability.Results. A good or excellent relative reliability were observed for SICI averaged at intervals 1.0–3.0 ms and 1.0–7.0 ms when assessed within a day or at different days. Relative reliability of SICI at separate interstimulus intervals varied in a wide range. SEM% was more than 10 % both for averaged SICI and SICI at all interstimulus intervals. Motor threshold had excellent reliability both assessed within a day and at different days, and low SEM values (5.6 % for Т1–Т2 and 4.39 % for Т1–Т3). High SEM and SEM% were observed for average MEP amplitude, it also had a moderate relative reliability when assessed within a day and a poor one – at different days.Conclusion. Calculation of averaged SICI can be recommended in further studies because of its high reliability values.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.