“…For a trial of 30-s duration (sampling frequency of 33 Hz), the force-platform system was linked to ST-150 software (Biomera, Moscow, Russia), thus providing CoP series on the anteroposterior (Y) and mediolateral (X) axes assessment ( Grohovsky and Kubryak, 2014 ). The dependent variables were calculated from the analysis of CoP trajectories.…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…For a trial of 30-s duration (sampling frequency of 33 Hz), the force-platform system was linked to ST-150 software (Biomera, Moscow, Russia), thus providing CoP series on the anteroposterior (Y) and mediolateral (X) axes assessment ( Grohovsky and Kubryak, 2014 ). The dependent variables were calculated from the analysis of CoP trajectories.…”
Section: Methodsmentioning
confidence: 99%
“…where m is the body weight, V the CoPD velocity, and n the number of discrete measurements conducted ( Grohovsky and Kubryak, 2014 ).…”
Section: Methodsmentioning
confidence: 99%
“…Such analysis makes it possible to assess the role of the cognitive component of postural control [ 42 , 43 ]. One of such integral indices, the energy expenditure for COP oscillations developed by French [ 44 ] and Russian [ 45 ] researchers, is calculated as a sum of the increments of kinetic energy (in Joules) ( Е ) determined by the change in the rate of displacement of the center of pressure at each discrete section of statokinesiogram (SKG) during the test. This index quantifies the functional activity required to maintain postural stability [ 44 , 45 ].…”
Section: Stabilometric Measurements Of Postural Controlmentioning
confidence: 99%
“…One of such integral indices, the energy expenditure for COP oscillations developed by French [ 44 ] and Russian [ 45 ] researchers, is calculated as a sum of the increments of kinetic energy (in Joules) ( Е ) determined by the change in the rate of displacement of the center of pressure at each discrete section of statokinesiogram (SKG) during the test. This index quantifies the functional activity required to maintain postural stability [ 44 , 45 ]. At present, computer technologies have been developed to measure postural stability by stabilometric [ 46 ] analysis, which can be performed even with smartphones [ 47 ].…”
Section: Stabilometric Measurements Of Postural Controlmentioning
confidence: 99%