1973
DOI: 10.1007/bf00815019
|View full text |Cite
|
Sign up to set email alerts
|

Metrological principles of thermophysical measurements (new book)

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
7
0

Year Published

2001
2001
2020
2020

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 6 publications
(7 citation statements)
references
References 0 publications
0
7
0
Order By: Relevance
“…The iron-rhodium thermometer used was calibrated by IST-90. The reliability of the calorimeter operation was tested by measuring the heat capacities of specialpurity copper (OSCh 11-4), standard synthetic corundum [5] and K-1 benzoic acid [5] prepared at metrological institutions of the State Standard Committee of Russian Federation. It was established that the apparatus and the measurement procedure allowed us to obtain the C p;m values of the substances in a condensed state with an uncertainty of not more than 2% from T = (6 to 10) K, 0.5% between T = (10 and 40) K, and within 0.2% in the range T = (40 to 355) K.…”
Section: Methodsmentioning
confidence: 99%
“…The iron-rhodium thermometer used was calibrated by IST-90. The reliability of the calorimeter operation was tested by measuring the heat capacities of specialpurity copper (OSCh 11-4), standard synthetic corundum [5] and K-1 benzoic acid [5] prepared at metrological institutions of the State Standard Committee of Russian Federation. It was established that the apparatus and the measurement procedure allowed us to obtain the C p;m values of the substances in a condensed state with an uncertainty of not more than 2% from T = (6 to 10) K, 0.5% between T = (10 and 40) K, and within 0.2% in the range T = (40 to 355) K.…”
Section: Methodsmentioning
confidence: 99%
“…a BKT-3 adiabatic vacuum calorimeter, was employed [7]. The reliability of the calorimeter operation was tested by measuring the standard molar heat capacity C p;m of standard K À 1 benzoic acid [8] and corundum [8] prepared at metrological institutions of the State Standard Committee of the Russian Federation. The (iron + rhodium) resistance thermometer used was calibrated on the basis of ITS-90.…”
Section: Methodsmentioning
confidence: 99%
“…(5) The calorimeter design and the operational procedure were substantially similar to those of a TAU-1 calorimeter described earlier. (6,7) The reliability of the calorimeter operation was tested by measuring the standard molar heat capacity C o p,m of standard K − 1 benzoic acid (8) and corundum (8) prepared at metrological institutions of the State Standard Committee of the Russian Federation. The (iron+rhodium) thermometer used was calibrated on the basis of ITS-90.…”
Section: Methodsmentioning
confidence: 99%