2022
DOI: 10.1038/s41398-021-01763-3
|View full text |Cite
|
Sign up to set email alerts
|

mGluR5 binding changes during a mismatch negativity task in a multimodal protocol with [11C]ABP688 PET/MR-EEG

Abstract: Currently, the metabotropic glutamate receptor 5 (mGluR5) is the subject of several lines of research in the context of neurology and is of high interest as a target for positron-emission tomography (PET). Here, we assessed the feasibility of using [11C]ABP688, a specific antagonist radiotracer for an allosteric site on the mGluR5, to evaluate changes in glutamatergic neurotransmission through a mismatch-negativity (MMN) task as a part of a simultaneous and synchronized multimodal PET/MR-EEG study. We analyzed… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
11
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
5
2

Relationship

4
3

Authors

Journals

citations
Cited by 12 publications
(11 citation statements)
references
References 72 publications
0
11
0
Order By: Relevance
“…Although, in this case, the effect of the global DTC compared to the block-pairwise DTC was rather small, there was a 2% difference in the BP ND . This difference can potentially mask the effects of cognitive challenges as described in (Régio Brambilla et al 2022), as it decreases over time and alters for different brain regions. Despite not being relevant for the present bolus-infusion protocol investigation, the early part of the TACs allow an important conclusion for dynamic studies using a bolus injection protocol and kinetic modeling to be drawn, which requires evaluation of the entire TAC to derive the BP ND outcome.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…Although, in this case, the effect of the global DTC compared to the block-pairwise DTC was rather small, there was a 2% difference in the BP ND . This difference can potentially mask the effects of cognitive challenges as described in (Régio Brambilla et al 2022), as it decreases over time and alters for different brain regions. Despite not being relevant for the present bolus-infusion protocol investigation, the early part of the TACs allow an important conclusion for dynamic studies using a bolus injection protocol and kinetic modeling to be drawn, which requires evaluation of the entire TAC to derive the BP ND outcome.…”
Section: Discussionmentioning
confidence: 99%
“…No further data processing was conducted for the phantom measurements. Constant true coincidence count rate framing schemes were used in all reconstructions to minimize reconstruction bias at low counts (Brambilla et al 2021, Régio Brambilla et al 2022). In the third measurement (III), five circular ROIs were specified in each compartment to enable the evaluation of accuracy and noise level.…”
Section: Methodsmentioning
confidence: 99%
“…In order to obtain metabolite-corrected plasma concentrations, the parent compound was separated from the metabolites in each sample by solid-phase extraction using appropriate cartridges (Waters Sep-Pak® tC18) as previously described. 29 Again, steady-state conditions of plasma activities during 45 - 60 min post bolus injection were ascertained visually and by a low coefficient of variance (mean, 4.8 ± 2.5%), and we averaged all four metabolite-corrected plasma concentrations. We calculated regional brain V T as follows: The radioligand concentration in the VOI (mean of 45 - 60 min) divided by metabolite-corrected plasma concentration (mean of 45 - 60 min).…”
Section: Methodsmentioning
confidence: 99%
“…In the first reconstruction, the listmode data were sorted into 5 min frames ('Const 5 min'). In the second reconstruction, the frames were reconstructed according to a method already presented [11,21] with a constant number of true coincidences in each frame ('Const Trues'), which minimizes and keeps the bias constant. For the 'Const Trues' scheme, PET true counts per frame based on this scheme were equivalent between subjects and also synchronized according to the fMRI RS acquisition moment.…”
Section: Pet Image Reconstruction and Bp Nd Estimationmentioning
confidence: 99%