2019
DOI: 10.1080/10408347.2019.1684235
|View full text |Cite
|
Sign up to set email alerts
|

Micro Solid Phase Extraction Using Novel Adsorbents

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
19
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 35 publications
(19 citation statements)
references
References 99 publications
0
19
0
Order By: Relevance
“…Subsequently, a target analyte is desorbed using appropriate eluent and analyzed by suitable instrumental techniques. [154][155][156][157] Common problems associated with column blocking, sorbent filling, high back pressure, and packet bed plugging in conventional SPE can be avoided using MSPE. 158,159 A magnetic sorbent material plays an essential role in determining the sensitivity and selectivity of the method.…”
Section: Magnetic Mof In Spementioning
confidence: 99%
See 1 more Smart Citation
“…Subsequently, a target analyte is desorbed using appropriate eluent and analyzed by suitable instrumental techniques. [154][155][156][157] Common problems associated with column blocking, sorbent filling, high back pressure, and packet bed plugging in conventional SPE can be avoided using MSPE. 158,159 A magnetic sorbent material plays an essential role in determining the sensitivity and selectivity of the method.…”
Section: Magnetic Mof In Spementioning
confidence: 99%
“…After the adsorption of the target analyte on the sorbent, the external magnetic field is applied to separate the magnetic adsorbent from the sample solution. Subsequently, a target analyte is desorbed using appropriate eluent and analyzed by suitable instrumental techniques 154–157 . Common problems associated with column blocking, sorbent filling, high back pressure, and packet bed plugging in conventional SPE can be avoided using MSPE 158,159 .…”
Section: Mof As a Sorbent In Solid‐phase Extractionmentioning
confidence: 99%
“…Various types of adsorbents [65][66][67] and formats [51,63,65] have been reported in the literature and they cover all potential interactions with the analytes [63,64]. This study will briefly review the application of MOFs in traditional SPE, DSPE, micro SPE (µ-SPE), pipette tip SPE (PT-SPE) and MSPE for environmental analysis.…”
Section: Solid Phase Extractionmentioning
confidence: 99%
“…As with other adsorption formats [14][15][16][17], FMNPs are the kernel of MSPE because they can affect the extraction performance of analytes significantly. So far, all kinds of materials such as carbon-based materials [18,19], molecularly imprinted polymers [20], metal-organic frameworks [21,22], and covalent organic frameworks [23] have been introduced to modify magnetic cores (typically, Fe 3 O 4 ). Although there are various adsorbents for MSPE, however, to efficiently capture different kinds of analytes, task-specific FMNPs should be designed and prepared according to the properties of targeted analytes.…”
Section: Introductionmentioning
confidence: 99%