2024
DOI: 10.1002/agt2.526
|View full text |Cite
|
Sign up to set email alerts
|

Microalbuminuria sensitive near‐infrared AIE probe for point‐of‐care evaluating kidney diseases

Zhirong Zhu,
Xiaoyan Chen,
Hongze Liao
et al.

Abstract: Urinary microalbumin (mALB) serves as an exceptionally sensitive indicator for the early detection of kidney damage, playing a pivotal role in identifying chronic renal failure and kidney lesions in individuals. Nevertheless, the current fluorescent methodologies for point‐of‐care (POC) diagnosis of mALB in real urine still exhibit suboptimal performance. Herein, the development and synthesis of QM‐N2, an albumin‐activated near‐infrared (NIR) aggregation‐induced emission (AIE) fluorescent probe, are presented.… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...

Citation Types

0
1
0

Year Published

2024
2024
2024
2024

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 7 publications
(1 citation statement)
references
References 37 publications
0
1
0
Order By: Relevance
“…In contrast, fluorescencebased analytical methods have emerged as promising alternatives for detecting HSA due to their simplified procedures, rapid response times, and enhanced selectivity. [7][8][9][10][11][12][13][14][15][16][17][18][19][20][21][22][23][24][25] However, most reported probes enable HSA detection based on changes in a single emission peak, which can be easily influenced by variations in analyte-independent factors, such as excitation source, photobleaching, and probe concentration. [26][27][28] Alternatively, a ratiometric fluorescent probe can provide a response signal dependent on the ratio of two emissions, rather than relying solely on a single emission.…”
mentioning
confidence: 99%
“…In contrast, fluorescencebased analytical methods have emerged as promising alternatives for detecting HSA due to their simplified procedures, rapid response times, and enhanced selectivity. [7][8][9][10][11][12][13][14][15][16][17][18][19][20][21][22][23][24][25] However, most reported probes enable HSA detection based on changes in a single emission peak, which can be easily influenced by variations in analyte-independent factors, such as excitation source, photobleaching, and probe concentration. [26][27][28] Alternatively, a ratiometric fluorescent probe can provide a response signal dependent on the ratio of two emissions, rather than relying solely on a single emission.…”
mentioning
confidence: 99%