2010
DOI: 10.1016/j.meatsci.2009.08.049
|View full text |Cite
|
Sign up to set email alerts
|

Microbial translocation of needle-free versus traditional needle injection-enhanced beef strip loins

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
7
0

Year Published

2012
2012
2022
2022

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 9 publications
(7 citation statements)
references
References 5 publications
0
7
0
Order By: Relevance
“…The movement of liquid within these channels could potentially carry E. coli O157 and, therefore, the position of translocated bacteria at the time of sampling and may not reflect initial bacterial translocation depth. Ray and others (2010) also observed the development of such channels at pressures > 0.2 MPa in their study using the one‐dose‐at‐a‐time needleless injector.…”
Section: Resultsmentioning
confidence: 81%
See 1 more Smart Citation
“…The movement of liquid within these channels could potentially carry E. coli O157 and, therefore, the position of translocated bacteria at the time of sampling and may not reflect initial bacterial translocation depth. Ray and others (2010) also observed the development of such channels at pressures > 0.2 MPa in their study using the one‐dose‐at‐a‐time needleless injector.…”
Section: Resultsmentioning
confidence: 81%
“…Studies measuring the effect of HPNI on microbial translocation using equipment made specifically for the purpose of enhancing meat with high‐pressure liquid jets are lacking. Ray and others (2010) used a manual, single‐injection‐at‐a‐time instrument, ordinarily used for livestock injections, on beef strip loins and concluded that E. coli could be translocated at 0.2 MPa. A study where the effect of high‐pressure water jets on the penetration of bacteria during beef carcass washing concluded that bacteria were more likely to be driven deeper into tissue as pressure increased (De Zuniga and others 1991).…”
Section: Introductionmentioning
confidence: 99%
“…Mechanical tenderization, which involves bladeor needle-piercing, could lead to increased transfer of surface pathogenic bacteria such as, Salmonella enterica and Escherichia coli O157:H7, into the previously sterile deep tissue (Gill et al, 2005;Huang, 2010;Jefferies et al, 2012;Saha et al, 2016). Furthermore, spoilage and pathogenic bacterial population could increase during reuse of a contaminated needle or blade (Greer et al, 2004;Ray et al, 2010;Jefferies et al, 2012). According to reports by the Centers for Disease Control and Prevention, mechanical tenderization of beef products has led to six outbreaks in the U.S., since 2000 (Heiman et al, 2015).…”
Section: Modeling Techniques For Prediction Of Safe Cooking Times Of mentioning
confidence: 99%
“…Many researchers have investigated the translocation of pathogenic bacteria from a product's surface to its interior (7,8,12,18,20). Phebus and colleagues (18) concluded that 3 to 4% of surface contamination was translocated to the center of the product, although most of the contamination occurs in the more superficial tissues.…”
mentioning
confidence: 99%