1977
DOI: 10.2307/3574640
|View full text |Cite
|
Sign up to set email alerts
|

Microdosimetry of Internal Sources

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
29
0

Year Published

1980
1980
2022
2022

Publication Types

Select...
5
2
1

Relationship

0
8

Authors

Journals

citations
Cited by 44 publications
(29 citation statements)
references
References 9 publications
0
29
0
Order By: Relevance
“…Therefore, no single value of energy or LET adequately describes the nature of the α-particle field to which the cells are exposed. In view of these considerations, a full microdosimetric analysis taking into account the finer aspects of target size, source distribution at the cellular level, hit probability, etc., is needed to obtain a better understanding of the RBE of incorporated radionuclides in vivo (39,41,42). The mouse testis model used in the present studies is not readily amenable to a microdosimetric analysis.…”
Section: Influence Of Microscopic Distribution Of Radioactivity On Rbementioning
confidence: 91%
“…Therefore, no single value of energy or LET adequately describes the nature of the α-particle field to which the cells are exposed. In view of these considerations, a full microdosimetric analysis taking into account the finer aspects of target size, source distribution at the cellular level, hit probability, etc., is needed to obtain a better understanding of the RBE of incorporated radionuclides in vivo (39,41,42). The mouse testis model used in the present studies is not readily amenable to a microdosimetric analysis.…”
Section: Influence Of Microscopic Distribution Of Radioactivity On Rbementioning
confidence: 91%
“…Other exceptions are a-or ß-emitting hot spots. These exceptional cases (see, e.g., [11][12][13]) are not treated in this chapter, but they can be of considerable radiobiological interest. Figure 1 serves as a rough illustration of the configuration of charged particle tracks.…”
Section: Nature Of the Problemmentioning
confidence: 99%
“…Concurrently, the Dosimetry Technology Section will develop cell and tissue models in which those methods will be applied. Computational methods for determining the microdosimetryof internally deposited alpha-emitting radionuclides were developed by W. C. Roesch to deal with the random nature of energy deposition in small tissue volumes (Roesch 1977). These complicated mathematical methods require the use of a large computer.…”
Section: • Microdosimetry Of Internal Sourcesmentioning
confidence: 99%
“…The solution also contained 5 x 10 6 macrophage cells/ml, which were assumed to be randomly mixed with the 241Am02 particulates. Using computational methods developed at this laboratory (Roesch 1977), the frequency distribution of specific energies (the average of which is the average absorbed dose) was calculated. Following the completion of this study, the effect of different concentrations of 241Am upon the specific energy distribution to the cells will be evaluated.…”
Section: • Dosimetry Of Internal Emittersmentioning
confidence: 99%