2020
DOI: 10.1016/j.mex.2020.101106
|View full text |Cite
|
Sign up to set email alerts
|

Microelectrodes from PEDOT-carbon nanofiber composite for high performance neural recording, stimulation and neurochemical sensing

Abstract: This present method describes a versatile approach for the electrochemical synthesis of a composite material of Poly (3,4-ethylenedioxythiophene) (PEDOT) and Carbon Nanofibers (CNFs) for neural interfaces and biosensing applications. Oxidized CNFs were utilized as dopants of PEDOT to prepare the composite coating through electrochemical deposition on microelectrodes arrays (MEA). The experimental results of this study showed that PEDOT:CNF microelectrodes exhibit remarkable electrochemical properties, combinin… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
8
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
7
3

Relationship

5
5

Authors

Journals

citations
Cited by 13 publications
(8 citation statements)
references
References 24 publications
0
8
0
Order By: Relevance
“…EIS and cyclic voltammetry (CV) were performed using a Bio-Logic VMP3 potentiostat. CV was performed in PBS at room temperature by potential sweeping between −0.6 and +0.6 V at 200 mV/s vs. Ag/ AgCl reference, allowing cathodal charge storage capacity (CSCc) evaluation 37,38 . EIS was also performed in PBS at room temperature by applying a 10 mV sine wave at frequencies ranging from 10 Hz to 7 MHz.…”
Section: Electrochemical Characterizationmentioning
confidence: 99%
“…EIS and cyclic voltammetry (CV) were performed using a Bio-Logic VMP3 potentiostat. CV was performed in PBS at room temperature by potential sweeping between −0.6 and +0.6 V at 200 mV/s vs. Ag/ AgCl reference, allowing cathodal charge storage capacity (CSCc) evaluation 37,38 . EIS was also performed in PBS at room temperature by applying a 10 mV sine wave at frequencies ranging from 10 Hz to 7 MHz.…”
Section: Electrochemical Characterizationmentioning
confidence: 99%
“…Raw CNFs (Pyrograf ® -III, PR-19-XT-PS, pyrolytically stripped, platelets conical, >98% carbon basis, 20-200 µm) were oxidized using wet chemical oxidation process where 300 mg of CNFs were placed in 200 ml of the oxidizing solution (15 M) HNO 3 /(18 M) H 2 SO 4 and sonicated for 15 min, followed by 2 h of reflux at 70 °C (Rasheed et al, 2007;Bortolamiol et al, 2014). This process helps to remove impurities (metallic particles and amorphous carbon) from the sample and make them hydrophilic, so that the CNFs can be dispersed in water (Saunier et al, 2020a). Following the acid treatment, the CNF dispersion was washed with DI water to reach a neutral pH, and stored at 4 °C.…”
Section: Functionalization Of Carbon Nanofibersmentioning
confidence: 99%
“…Electrochemical Impedance Spectroscopy (EIS) and Cyclic Voltammetry (CV) methods were performed using a Bio-Logic VMP3 potentiostat. CV was performed in Phosphate Buffered Saline (Gibco DPBS 1X) at room temperature by potential sweeping between -0.6 V and +0.6 V vs. Ag/AgCl reference at 200 mV/s, allowing cathodal Charge Storage Capacity (CSCc) evaluation [34][35] . EIS was also performed in PBS at room temperature by applying 10 mV sine wave at frequencies ranging from 10 Hz to 7 MHz.…”
Section: Electrochemical Characterizationsmentioning
confidence: 99%