2022
DOI: 10.1016/j.sampre.2022.100031
|View full text |Cite
|
Sign up to set email alerts
|

Microextraction columns for automated sample preparation. A review focusing on fully miniaturized column switching and bioanalytical applications

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
5
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
4

Relationship

2
2

Authors

Journals

citations
Cited by 4 publications
(5 citation statements)
references
References 111 publications
0
5
0
Order By: Relevance
“…Sample preparation is often a critical first step in the analysis of complex samples in a variety of matrices. Recently, efforts have been made to automate sample preparation techniques to improve method throughput and reproducibility [20][21][22]. Frequently, microcontrollers are used to control the movement systems associated with these automated sample preparation techniques [23], especially in connection with open-source stepper motor driver boards (e.g., the RepRap Arduino Mega Pololu Shield, or RAMPS, board).…”
Section: Sample Preparationmentioning
confidence: 99%
“…Sample preparation is often a critical first step in the analysis of complex samples in a variety of matrices. Recently, efforts have been made to automate sample preparation techniques to improve method throughput and reproducibility [20][21][22]. Frequently, microcontrollers are used to control the movement systems associated with these automated sample preparation techniques [23], especially in connection with open-source stepper motor driver boards (e.g., the RepRap Arduino Mega Pololu Shield, or RAMPS, board).…”
Section: Sample Preparationmentioning
confidence: 99%
“…Research using OT columns as extraction/preconcentration columns (first dimension) in column-switching methods has significantly developed new coatings to retain many analytes [133]. For example, Kataoka et al [134] reported the use of PLOT columns (60 cm × 0.32 mm i.d.)…”
Section: Application Of Ot Columns In Column-switching Lcmentioning
confidence: 99%
“…In general, the diversity of OT coatings for extractive purses superates the ones employed in analysis and separation, possibly due to the short length of the extractive columns, which facilitates its preparation. Critical reviews have recently been introduced summarizing the vast diversity of OT coatings for extractive porpuses [133,[137][138][139][140][141]. Table 2 shows some selected examples of diverse coating and its potential to retain analytes in a broad polarity range.…”
Section: Application Of Ot Columns In Column-switching Lcmentioning
confidence: 99%
“…Therefore, studies employing direct and indirect determination methods for pesticide exposure have been conducted (16), with human biomonitoring enabling the measurement of personal exposure to specific chemicals, including both unmetabolized and metabolized compounds (17). This is typically achieved through the analysis of biological samples like blood, plasma, serum, and urine, frequently complemented with oral fluid, hair, and nails, employing methods that must be fast, sensitive, and specific, emphasizing miniaturization and automation (18,19). Technological advancements have led to increasingly sensitive detection methods capable of measuring pesticides accurately in parts per billion (ng•mL −1 , or μg•kg −1 ), even with less expensive instrumentation and simplified approaches (20).…”
Section: Introductionmentioning
confidence: 99%
“…This is typically achieved through the analysis of biological samples like blood, plasma, serum, and urine, frequently complemented with oral fluid, hair, and nails, employing methods that must be fast, sensitive, and specific, emphasizing miniaturization and automation ( 18 , 19 ). Technological advancements have led to increasingly sensitive detection methods capable of measuring pesticides accurately in parts per billion (ng·mL −1 , or μg·kg −1 ), even with less expensive instrumentation and simplified approaches ( 20 ).…”
Section: Introductionmentioning
confidence: 99%