Microscopic Gold Particle-Based Fiducial Markers for Proton Therapy of Prostate Cancer

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
25
0

Year Published

2012
2012
2019
2019

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 31 publications
(25 citation statements)
references
References 37 publications
0
25
0
Order By: Relevance
“…While MCS is important, energy loss in the fiducial (or its water-equivalent thickness), the proximity of the fiducial to the end of the proton beam range, and of course its size and orientation with respect to the beam also should be considered. The physics of dose perturbations is explained in detail elsewhere (Newhauser et al, (2007a), and several subsequent studies (Giebeler et al , 2009; Lim et al , 2009; Cheung et al , 2010; Huang et al , 2011) have shown that it is possible to achieve good radiographic visibility using novel markers that do not significantly perturb the therapeutic dose distribution in tissue.…”
Section: Proton Interaction Mechanismsmentioning
confidence: 99%
“…While MCS is important, energy loss in the fiducial (or its water-equivalent thickness), the proximity of the fiducial to the end of the proton beam range, and of course its size and orientation with respect to the beam also should be considered. The physics of dose perturbations is explained in detail elsewhere (Newhauser et al, (2007a), and several subsequent studies (Giebeler et al , 2009; Lim et al , 2009; Cheung et al , 2010; Huang et al , 2011) have shown that it is possible to achieve good radiographic visibility using novel markers that do not significantly perturb the therapeutic dose distribution in tissue.…”
Section: Proton Interaction Mechanismsmentioning
confidence: 99%
“…[5][6][7] Several proposals to mitigate dose distortion have been made such as the reduction of marker size, 7 the optimization of marker compounds with carbon-coated ceramic 8 or mixture of microscopic gold particles and polymers. 9 An alternate solution may be to diminish the dose distortion effect by increasing the number of fields. 10 Because proton pencil beam scanning technique does not require replacement of the apertures and range compensators field by field, the treatment time will not be increased so much by the use of multiple fields.…”
Section: Introductionmentioning
confidence: 99%
“…In such a scenario, the analysis of the detected spectrum could assess whether the metallic structure was or was not located along the beam path during the treatment. Further clinical applicability may include patient with implanted seeds 45,46 . In general, this considerations are valid for high‐Z materials that, in contrast to light nuclei, emit prompt gamma radiation mainly in the low‐energy component of the spectrum.…”
Section: Discussionmentioning
confidence: 99%
“…Further clinical applicability may include patient with implanted seeds. 45,46 In general, this considerations are valid for high-Z materials that, in contrast to light nuclei, emit prompt gamma radiation mainly in the low-energy component of the spectrum. Additionally, the annihilation line E c ¼ 0:511 MeV could also be measured (not shown).…”
Section: Discussionmentioning
confidence: 99%