2016
DOI: 10.1016/j.corsci.2016.02.014
|View full text |Cite
|
Sign up to set email alerts
|

Microstructural, electrochemical and tribo-electrochemical characterisation of titanium-copper biomedical alloys

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

1
19
0
1

Year Published

2017
2017
2020
2020

Publication Types

Select...
6
2

Relationship

0
8

Authors

Journals

citations
Cited by 60 publications
(21 citation statements)
references
References 35 publications
1
19
0
1
Order By: Relevance
“…As a consequence of wear-corrosion processes taking place at implant/ bone interface, wear debris and corrosion products may be released to the implant surroundings and induce to adverse biological reactions and, ultimately, lead to implant loosening [17][18][19]. Various studies have been recently conducted to investigate the degradation of Ti-based implant materials by tribocorrosion processes [20][21][22][23][24][25][26][27][28]. In spite of the negative impact that tribocorrosion processes may have on the long term biological and mechanical stability of dental implants, the development of new implant systems addressing an integrated approach, which includes wear-corrosion resistance as a pre-requisite for implant success, is still lacking [29].…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…As a consequence of wear-corrosion processes taking place at implant/ bone interface, wear debris and corrosion products may be released to the implant surroundings and induce to adverse biological reactions and, ultimately, lead to implant loosening [17][18][19]. Various studies have been recently conducted to investigate the degradation of Ti-based implant materials by tribocorrosion processes [20][21][22][23][24][25][26][27][28]. In spite of the negative impact that tribocorrosion processes may have on the long term biological and mechanical stability of dental implants, the development of new implant systems addressing an integrated approach, which includes wear-corrosion resistance as a pre-requisite for implant success, is still lacking [29].…”
Section: Introductionmentioning
confidence: 99%
“…Furthermore, these nanostructures have shown the ability to display antimicrobial properties and thus inhibit microbial infections [37][38][39][40][41][42][43][44][45]. Additionally, TiO 2 nanotubes possess a lower elastic modulus (36-43 GPa) than cp-Ti (120-166 GPa), which is closer to that of natural bone (11)(12)(13)(14)(15)(16)(17)(18)(19)(20)(21)(22)(23)(24)(25)(26)(27)(28)(29)(30), and thus TiO 2 nanotubular structured Ti surfaces are expected to have improved biomechanical compatibility, by reducing stress shielding effect [46][47][48][49].…”
Section: Introductionmentioning
confidence: 99%
“…After screening full texts, a total of 44 studies were included considering the tribocorrosion analyses for dental implants and frameworks applications. The characteristics of the 44 studies (Vieira et al, 2006;Banu et al, 2008;Richard et al, 2010;Souza et al, 2010aSouza et al, , 2012Sivakumar et al, 2011;Dimah et al, 2012;Mardare et al, 2012;Mathew et al, 2012a,b;Albayrak et al, 2013;Alves et al, 2013Alves et al, , 2014Alves et al, , 2017Alves et al, , 2018Benea et al, 2013Benea et al, , 2015Benea et al, , 2017Licausi et al, 2013a,b;Fazel et al, 2015;Figueiredo-Pina et al, 2015;Golvano et al, 2015;Oliveira et al, 2015;Buciumeanu et al, 2016Buciumeanu et al, , 2017Correa et al, 2016;Guinon Pina et al, 2016;Marques et al, 2016;Mindivan et al, 2016;Pontes et al, 2016;Sampaio et al, 2016b;Silva et al, 2016;Bryant and Neville, 2017;Danaila and Benea, 2017;Mindivan and Mindivan, 2018;Sikora et al, 2018;Trino et al, 2018;Wang et al, 2018;Branco et al, 2019;Corne et al, 2019;Cui et al, 2019a,b;…”
Section: The Relevance Of Bio-tribocorrosion In Dentistry and State Omentioning
confidence: 99%
“…It was reached a current plateau and there was no transpassivation in potentials up to 8 V [6,[13][14] . There was also no pitting corrosion in all the Ti-Mo alloys exposed in the different solutions during the potential scans, suggesting their high resistance even in the presence of fluoride ions, which did not avoid the formation of the passive film probably due to the small amount of HF in the solution, nevertheless these ions can dissolve the passive film due to the formation of TiF3, TiF4 and TiOF2 [13] , expressed in the (1), (2) and 3reactions: prevent dental caries [14][15][16] .…”
Section: Cyclic Voltammetry (Cv)mentioning
confidence: 99%
“…It is a localized corrosion that is very harmful because it causes a corrosive attack that penetrates into the matrix of the alloy and makes the mechanical properties weaker. Besides the good corrosion resistance of the titanium alloys, their wide application is explained by their biocompatibility and mechanical properties as low Young's modulus, high yield and tensile strength [1,2] .…”
Section: Introductionmentioning
confidence: 99%