Microwave bone imaging: a preliminary scanning system for proof‐of‐concept

Abstract: This Letter introduces a feasibility study of a scanning system for applications in biomedical bone imaging operating in the microwave range 0.5–4 GHz. Mechanical uncertainties and data acquisition time are minimised by using a fully automated scanner that controls two antipodal Vivaldi antennas. Accurate antenna positioning and synchronisation with data acquisition enables a rigorous proof-of-concept for the microwave imaging procedure of a multi-layer phantom including skin, fat, muscle and bone tissues. The… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
38
0
1

Year Published

2019
2019
2024
2024

Publication Types

Select...
5
1

Relationship

0
6

Authors

Journals

citations
Cited by 47 publications
(39 citation statements)
references
References 15 publications
0
38
0
1
Order By: Relevance
“…The authors in [18] performed a study for bone imaging, collecting the signals in multi-monostatic fashion and using antennas immersed in a coupling liquid. In [18], imaging was performed using a beamforming procedure named non-coherent migration, after applying an average trace subtraction strategy to remove the artefact.…”
Section: Resultsmentioning
confidence: 99%
See 4 more Smart Citations
“…The authors in [18] performed a study for bone imaging, collecting the signals in multi-monostatic fashion and using antennas immersed in a coupling liquid. In [18], imaging was performed using a beamforming procedure named non-coherent migration, after applying an average trace subtraction strategy to remove the artefact.…”
Section: Resultsmentioning
confidence: 99%
“…The authors in [18] performed a study for bone imaging, collecting the signals in multi-monostatic fashion and using antennas immersed in a coupling liquid. In [18], imaging was performed using a beamforming procedure named non-coherent migration, after applying an average trace subtraction strategy to remove the artefact. Instead, here, we collect the signals in multi-bistatic fashion, using antennas in free space; imaging was performed using an HP based algorithm, which operated in the frequency domain, after applying a rotation subtraction strategy to remove the artefact.…”
Section: Resultsmentioning
confidence: 99%
See 3 more Smart Citations