2019
DOI: 10.1021/acssuschemeng.8b04655
|View full text |Cite
|
Sign up to set email alerts
|

Microwave-Mediated Site-Selective Heating of Spherical-Carbon-Bead-Supported Platinum for the Continuous, Efficient Catalytic Dehydrogenative Aromatization of Saturated Cyclic Hydrocarbons

Abstract: A microwave (MW)-assisted method for the continuous production of hydrogen from methylcyclohexane using platinum on spherical carbon beads has been developed, and its application to the efficient dehydrogenative aromatization of fully saturated cyclic alkanes, including piperidines as representative heterocycles, has been studied. Effective dehydrogenation was achieved by the construction of a highly intense energy field, which acted as a reactive site, on the irradiation of the carbon beads (CB) support. The … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
14
0

Year Published

2019
2019
2023
2023

Publication Types

Select...
4
2
1

Relationship

1
6

Authors

Journals

citations
Cited by 27 publications
(14 citation statements)
references
References 60 publications
0
14
0
Order By: Relevance
“…The reaction system is shown in Figure 3. When the catalyst-packed cartridge equipped with a thermocouple was set in the microwave cavity, the catalyst was located on the horizontal center line in the microwave cavity [39]. This device uses a solid-state oscillator and can change the frequency of the irradiated microwave based on the shift in the resonant frequency in 1-W increments between 1-50 W, and the resonant frequency was always monitored during microwave irradiation.…”
Section: Reaction Systemmentioning
confidence: 99%
See 2 more Smart Citations
“…The reaction system is shown in Figure 3. When the catalyst-packed cartridge equipped with a thermocouple was set in the microwave cavity, the catalyst was located on the horizontal center line in the microwave cavity [39]. This device uses a solid-state oscillator and can change the frequency of the irradiated microwave based on the shift in the resonant frequency in 1-W increments between 1-50 W, and the resonant frequency was always monitored during microwave irradiation.…”
Section: Reaction Systemmentioning
confidence: 99%
“…Straight cartridge. The 5% Pt/CB (80 mg, Pt: 20.5 μmol)-packed cartridge was prepared according to the procedure demonstrated in our recently reported literature [39]. Glass beads (0.991-1.397-mm diameter, 2.01 g) were packed on the glass filter, which reached the narrow part over the partially bulging part of the straight glass tube, and then a small amount of glass wool was packed on the glass beads.…”
Section: Preparation Of Catalyst Cartridgementioning
confidence: 99%
See 1 more Smart Citation
“…1). 8 When methylcyclohexane (MCH, 220 mL) was passed through a straight-tube reactor filled with Pt catalyst mounted on carbon beads and heated by AFT MW (10 W applied power) at 0.5 mL/min for 12 h of recirculation, 34 L of pure H2 gas was collected. This represented an energy-efficient method for H2 production, because the reflected MW power was only 1 W (90% heating efficiency) with a catalyst TON of ca.…”
Section: Heterogeneous Reactionsmentioning
confidence: 99%
“…1000 mol Lcat -1 h -1 , far superior to the rivalling organic chemical hydride (K-Pt/Al2O3-catalyzed) technology at 46 mol Lcat -1 h -1 . 8 This process has great promises for H2 storage and transfer hydrogenation applications, because hydrogenation of aromatic rings (the reverse reaction) can be readily achieved under Pd catalysis. Therefore, it is an example of a functional material synthesis.…”
Section: Heterogeneous Reactionsmentioning
confidence: 99%