1984
DOI: 10.1364/ao.23.002970
|View full text |Cite
|
Sign up to set email alerts
|

Mini laser-Doppler (blood) flow monitor with diode laser source and detection integrated in the probe

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
33
0

Year Published

2001
2001
2012
2012

Publication Types

Select...
5
3

Relationship

0
8

Authors

Journals

citations
Cited by 66 publications
(33 citation statements)
references
References 6 publications
0
33
0
Order By: Relevance
“…The idea of miniaturizing the laser Doppler flowmeter and avoiding fiber movement artifacts has led to the concept of an integrated probe for laser Doppler perfusion monitoring [44]. de Mul et al [44] developed a probe (∅16 mm, length 13 mm) in which a solid-state diode laser source (AlGaAs, 5 mW, 840 nm) and detectors were integrated.…”
Section: Integrated Systemsmentioning
confidence: 99%
See 1 more Smart Citation
“…The idea of miniaturizing the laser Doppler flowmeter and avoiding fiber movement artifacts has led to the concept of an integrated probe for laser Doppler perfusion monitoring [44]. de Mul et al [44] developed a probe (∅16 mm, length 13 mm) in which a solid-state diode laser source (AlGaAs, 5 mW, 840 nm) and detectors were integrated.…”
Section: Integrated Systemsmentioning
confidence: 99%
“…de Mul et al [44] developed a probe (∅16 mm, length 13 mm) in which a solid-state diode laser source (AlGaAs, 5 mW, 840 nm) and detectors were integrated. This avoided Fig.…”
Section: Integrated Systemsmentioning
confidence: 99%
“…In order to implement such a system the relatively large Helium-Neon laser has to be replaced by a laser diode source. This was achieved by De Mul et al (1984) who reported a compact integrated probe containing a visible laser diode and two photodiodes. This solution has not been widely adopted in conu-nercial systems, primarily because the use of fibre optics allows the use of 68 interchangeable probe heads that are optimised for particular sites on the body.…”
Section: Evolution Of Laser Doppler Signal Processing Algorithmsmentioning
confidence: 99%
“…Data was downloaded off-line for processing, allowing different signal processing approaches to be evaluated. (Drain 1980, Oberg 1990), De Mul (1984 for example, states a SNR power ratio of 10.…”
mentioning
confidence: 99%
“…The particle speed can be expressed as a function of the frequency fluctuations (f r ) of the scattered intensity and of the distance between two contiguous fringes (γ) as follows: (6) being θ the angle between the two beams. Some works were carried out to realize compact laser Doppler-based instruments [75]. The aim was to create devices that integrate all the optical components of the laser Doppler flowmeter.…”
Section:  Laser Doppler Flowmetermentioning
confidence: 99%