Mismatched Disturbance Rejection Control for Voltage-Controlled Active Magnetic Bearing via State-Space Disturbance Observer

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
36
0

Year Published

2016
2016
2024
2024

Publication Types

Select...
3
3
1

Relationship

0
7

Authors

Journals

citations
Cited by 79 publications
(36 citation statements)
references
References 33 publications
0
36
0
Order By: Relevance
“…duced in the previous section is adopted to generate the 2n s α-β current references from the required x − y forces and torque references. The transformation from static to rotating reference frame is defined by means (14) and applied to (10).…”
Section: Experimental Results Of the Vibration Suppressionmentioning
confidence: 99%
See 2 more Smart Citations
“…duced in the previous section is adopted to generate the 2n s α-β current references from the required x − y forces and torque references. The transformation from static to rotating reference frame is defined by means (14) and applied to (10).…”
Section: Experimental Results Of the Vibration Suppressionmentioning
confidence: 99%
“…The approximated vector of the current demand required to develop the reference mechanical outputW * E can be then expressed as in (10).…”
Section: A Pseudo Inverse Matrixmentioning
confidence: 99%
See 1 more Smart Citation
“…In [12], a modified ADRC method was used in a 6-degree-of-freedom parallel platform and the platform could be driven to follow the given references well. Furthermore, the ADRC method has been used in magnetic rodless pneumatic cylinder [13], electromagnetic linear actuator [14], multimotor servomechanism [15] and magnetic bearing [16]. However, compared with the traditional ADRC method which is nonlinear, a linear active disturbance rejection control (LADRC) method has also been developed for controller design.…”
Section: Introductionmentioning
confidence: 99%
“…However, the ADRC method and the LADRC method both have more tuning parameters than the traditional PID method, while the appropriate controller parameters depend on the experiences of experts. Sometime, the number of the ADRC method parameters can be reduced to one or two [16,20]. To compare the traditional ADRC method and the LADRC method clearly, this paper does not reduce parameters.…”
Section: Introductionmentioning