2021
DOI: 10.1080/02656736.2021.1899310
|View full text |Cite
|
Sign up to set email alerts
|

Mitigation of magnetic particle hyperthermia side effects by magnetic field controls

Abstract: Objective: In magnetic particle hyperthermia, a promising least-invasive cancer treatment, malignant regions in proximity with magnetic nanoparticles undergo heat stress, while unavoidably surrounding healthy tissues may also suffer from heat either directly or indirectly by the induced eddy currents, due to the developed electric fields as well. Here, we propose a facile upgrade of a typical magnetic particle hyperthermia protocol, to selectively mitigate eddy currents' heating without compromising the benefi… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
16
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
6
1

Relationship

1
6

Authors

Journals

citations
Cited by 22 publications
(16 citation statements)
references
References 47 publications
0
16
0
Order By: Relevance
“…In order to test the reliability of the proposed strategy, the numerical results were compared to the corresponding experimental ones, as obtained in [ 23 ] after temperature measurements, by applying either a continuous AMF or a PMF of 45 mT, as shown in Figure 11 .…”
Section: Resultsmentioning
confidence: 99%
See 3 more Smart Citations
“…In order to test the reliability of the proposed strategy, the numerical results were compared to the corresponding experimental ones, as obtained in [ 23 ] after temperature measurements, by applying either a continuous AMF or a PMF of 45 mT, as shown in Figure 11 .…”
Section: Resultsmentioning
confidence: 99%
“…One way to express the ratio between ON and OFF times is the Duty Cycle, shown in Equation (1). The role of pulsed AMF—that is, Duty Cycles—to reducing eddy current heating was based on our previously reported study [ 23 ]. This quantity is defined as the percentage of the time the coil is in operation (ON) to the total time of a cycle (ON + OFF).…”
Section: Methodsmentioning
confidence: 99%
See 2 more Smart Citations
“…Temperature was regulated by varying the pulse for a specific amplitude and duty combination and finally the choice of the duty and cycle at amplitudes greater than 700 Oe was considered to prevent damage to the healthy tissues. Similarly, the optimum condition of intermittent field was also considered in [32]. The duty cycle of 33% with the ON/OFF condition of 50/100 in second for the intermittent magnetic field mode was shown to mitigate the eddy current in normal tissues.…”
Section: Introductionmentioning
confidence: 99%