Mitigation of Voltage Sag and Swell Using Direct Converters with Minimum Switch Count

Abstract: A new simplified topology for a dynamic voltage restorer (DVR) based on direct converter with a reduced number of switches is presented. The direct converter is fabricated using only three bi-directional controlled switches. The direct converter is connected between the grid and center-tapped series transformer. The center-tapped series transformer is used to inject the compensating voltage synthesized by the direct converter. The DVR can properly compensate for long-duration, balanced, and unbalanced voltage … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2

Citation Types

0
2
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
2

Relationship

0
2

Authors

Journals

citations
Cited by 2 publications
(2 citation statements)
references
References 17 publications
0
2
0
Order By: Relevance
“…The voltage sags are also caused by starting of large motors, switching of large loads, energizing of transformers and equipment faults. Most of these faults (70-80%) will be self-cleared within a few milliseconds as explained in [5][6][7]. IEEE Standard 1100-1992 in IEEE Emerald Book defines voltage sag as, "a rms reduction in the AC voltage from 90% to 10% of nominal supply, at the power frequency, for durations from a half-cycle to a few seconds".…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…The voltage sags are also caused by starting of large motors, switching of large loads, energizing of transformers and equipment faults. Most of these faults (70-80%) will be self-cleared within a few milliseconds as explained in [5][6][7]. IEEE Standard 1100-1992 in IEEE Emerald Book defines voltage sag as, "a rms reduction in the AC voltage from 90% to 10% of nominal supply, at the power frequency, for durations from a half-cycle to a few seconds".…”
Section: Introductionmentioning
confidence: 99%
“…Many DVR topologies are presented in the literature survey. DVRs based on direct converters are presented in [6,7], in which power required for compensation is taken from the AC supply side and AC/AC direct converters are used to generate compensating voltage for mitigating voltage sag and swell. In this topologies, single phase outage or three phase outages can't be compensated as there is no voltage available at the supply side during outage.…”
Section: Introductionmentioning
confidence: 99%