2006
DOI: 10.1016/j.echo.2005.10.006
|View full text |Cite
|
Sign up to set email alerts
|

Mitral Peak Doppler E-wave to Peak Mitral Annulus Velocity Ratio Is an Accurate Estimate of Left Ventricular Filling Pressure and Predicts Mortality in End-stage Renal Disease

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

6
96
1

Year Published

2007
2007
2024
2024

Publication Types

Select...
8
1

Relationship

0
9

Authors

Journals

citations
Cited by 128 publications
(103 citation statements)
references
References 39 publications
6
96
1
Order By: Relevance
“…However, there is so far no comparative study on the diagnostic value of the E/Em ratio in dialysis patients compared with heart failure patients without renal failure. In an ESRD population, an E/Em ratio Ն15 was associated with a sensitivity of 82% and a specificity of 88% in predicting LV end-diastolic pressure Ͼ15 mmHg (14). Our recent study shows that increasing age, systolic dysfunction, LV volume index, and loss of residual renal function are all significant, independent predictors of an E/Em ratio Ն15 in ESRD.…”
Section: Discussionmentioning
confidence: 75%
“…However, there is so far no comparative study on the diagnostic value of the E/Em ratio in dialysis patients compared with heart failure patients without renal failure. In an ESRD population, an E/Em ratio Ն15 was associated with a sensitivity of 82% and a specificity of 88% in predicting LV end-diastolic pressure Ͼ15 mmHg (14). Our recent study shows that increasing age, systolic dysfunction, LV volume index, and loss of residual renal function are all significant, independent predictors of an E/Em ratio Ն15 in ESRD.…”
Section: Discussionmentioning
confidence: 75%
“…Numerous studies have shown a correlation of the E/e ratio with adverse events after acute myocardial infarction, hypertensive cardiomyopathy, and ESRD. [30][31][32][33] The velocity of e is dependent on changes of preload, afterload, the procedure should be performed in selected patients during the early period of dialysis treatment. Furthermore, early implementation of the procedure might improve patients' survival after transplantation.…”
Section: 28mentioning
confidence: 99%
“…Tissue Doppler is less sensitive to alterations in preload, being important in the categorization of LV diastolic function 11 and is an independent predictor of death and cardiovascular events in patients with CKD 29,30 . The only study that evaluated the evolution of tissue Doppler before and after kidney transplantation showed that the e' wave increased significantly from 5.6 cm/s to 6.5 cm/s in a follow-up of 4.2 years 29 , indicating an improvement of diastolic function.…”
Section: Discussionmentioning
confidence: 99%