“…Thus, it can be concluded that I should be hydrogenated in EtOH at 45°C over AV-17-8-Pd and AN-1-Pd catalysts, which are superior to the heterogeneous catalyst Pd/C with respect to selectivity and stability and can produce high-quality VII without special purification [7].…”
Section: Synthesis Of Anesthesinmentioning
confidence: 99%
“…We demonstrated several times the ability in principle to perform simuntaneous hydrogenation of the nitro group and trans-esterification of the ester over Pd-containing polymers [7,16,17]. Hydrogenation of I and trans-esterification of the resulting VII was carried out over Pd/C, AV-17-8-Pd, and AN-1-Pd.…”
Catalytic processes involving Pd-containing catalysts for the synthesis of local anesthetics such as anesthesin (benzocaine), novocaine (procaine), lidocaine, mepivacaine, bupivacaine, trimecaine, and pyromecaine (bumecaine) are reviewed.
“…Thus, it can be concluded that I should be hydrogenated in EtOH at 45°C over AV-17-8-Pd and AN-1-Pd catalysts, which are superior to the heterogeneous catalyst Pd/C with respect to selectivity and stability and can produce high-quality VII without special purification [7].…”
Section: Synthesis Of Anesthesinmentioning
confidence: 99%
“…We demonstrated several times the ability in principle to perform simuntaneous hydrogenation of the nitro group and trans-esterification of the ester over Pd-containing polymers [7,16,17]. Hydrogenation of I and trans-esterification of the resulting VII was carried out over Pd/C, AV-17-8-Pd, and AN-1-Pd.…”
Catalytic processes involving Pd-containing catalysts for the synthesis of local anesthetics such as anesthesin (benzocaine), novocaine (procaine), lidocaine, mepivacaine, bupivacaine, trimecaine, and pyromecaine (bumecaine) are reviewed.
“…Unknown and specified organic impurities are commonly identified using a mass spectrometer [117,124,[127][128][129][130][131]. Such selective detectors as electron-capture and flame-photometric detectors are used extremely rarely.…”
Section: Determination Of Organic Impurities In Pharmaceutical Preparmentioning
Data reported in the literature on methods for the determination of organic impurities in pharmaceutical preparations are systematized; the characteristics and possibilities of the methods are compared.
“…Such selective detectors as electron-capture and flame-photometric detectors are used extremely rarely. Unknown and specified organic impurities are commonly identified using a mass spectrometer [117,124,[127][128][129][130][131]. The identification of specified impurities is particularly important when solvents of the first group are used.…”
Section: Determination Of Organic Impurities In Pharmaceutical Preparmentioning
confidence: 99%
“…In addition, the quality of information on the structure of the molecule can be improved using tandem MS. Soft chemical ionization makes it possible to obtain information of the molecular mass of the molecule. Methodological approaches to the determination of the structure of specific impurities in medicinal preparations using GC-MS were considered in several works [127,129,[131][132][133].…”
Section: Determination Of Organic Impurities In Pharmaceutical Preparmentioning
Data reported in the literature on methods for the determination of organic impurities in pharmaceutical preparations are systematized; the characteristics and possibilities of the methods are compared.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.